Installation, Use and Maintenance Guide 

   

 

Stove body WAIR6 

– WAIR6 WITH AIRBOX 1 

 

 

Stove body WAIR8 

– WAIR8 WITH AIRBOX 1 

 

 

 

 SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 

7.1 FOREWORD 

Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared 
the  following  paragraph  to  assist  the  installer  in  his  inspection  of  the  parts  concerned  with  eliminating  the  gases 
produced by combustion. 
 
The smoke outlet must be fitted in compliance with standard UNI UNI7129/92 and UNI 10683 and it must observe the 
reference values laid down in the standard, in particular, the outlet must comply with fire prevention regulations. 

It is important to carefully follow the instructions set out below: failure to observe these instructions could 
cause serious damage to the product, to the system, to objects and to persons using the appliance.
 
 

7.2 ROOM VENTILATION 

ATTENTION: the presence of extraction fans or similar appliances, if operating in the same room or space in which the 
product is installed, could cause problems for the correct operation of the product. 
ATTENTION: do not obstruct the vents or the air inlets on the appliance. 

 
The room where the appliance is installed must have a good air flow to guarantee air for the appliance for the combustion process 
and for ventilation of the room. The natural air flow must take place directly through permanent openings on the outer walls or through 
single or multiple ventilation ducting. 
The ventilation air intake must be located away from pollution sources. 
The openings in the walls must comply with the following conditions: 
• have an unobstructed section of at least 6cm² for each Kw of installed thermal power, with a minimum limit of 100cm²; 
• be made in such a way that the vent openings, both on the inside and outside of the wall, cannot be obstructed; 
• be protected with grills or similar systems that do not reduce the opening section indicated above; 
• be situated at a height near floor level and they must not obstruct the correct operation of the combustion product discharge devices; 
if this position is not possible the section of the ventilation openings must be enlarged by at least 50%. 

7.3 SMOKE OUTLET 

The smoke channel, the exhaust pipe, chimney and flue outlet (defined as the system for the evacuation of combustion 
products), are parts of the heating system and they must comply with the legislative requirements of the Ministerial 
Decree DM 37/08 (ex Italian Law 46/90) and to the applicable specific installation regulations, according to the type of 
fuel. Fireplaces, stoves and barbecues must not be installed in locations where gas appliances type A and type B are 
present and operating (for the classification see UNI 10642 and UNI 7129). The connection between the appliance and 
the flue outlet must only receive exhaust from one heat generator. 
The installer must provide one or more access points on the flue outlet to check the emissions once the appliance has 
been installed; these access points must be made in such a way as to be air-tight sealable to prevent exhaust gas 
leaks. 
It is recommended to provide insulation and to ensure the optimal sizing of the flue outlet in order to avoid the possible 
risk of condensation forming in the flue outlet. 

7.3.1 CHIMNEY TYPES 

The following types of chimneys, constructed as described, are possible: 
• System: Chimney installed using a combination of compatible components (flue liner, insulation, outer casing etc…), constructed or 
specified by a single manufacturer and CE certified in accordance with the applicable standard; 
• Composite chimney: Chimney installed or constructed on site using a combination of compatible components such as flue liner (wall 
directly in contact with the smoke), and possibly also insulation and outer casing (wall) that may be supplied by different manufacturers 
or by the same manufacturer. 
•  Relining:  operation  involving  the  installation  of  a  specific  pipe  in  an  existing  shaft  (even  if  newly  constructed)  made  of  non-
combustible materials, free from obstructions and for single use. 
 

 

Содержание WAIR6

Страница 1: ......

Страница 2: ...NG 21 4 4 UNPACKING MOUNTING THE DORICA MAIOLICA CASING 21 4 5 UNPACKING MOUNTING THE AROMY CASING 21 4 6 UNPACKING MOUNTING THE AROMY STONE CASING 21 4 7 UNPACKING MOUNTING THE SAINT MORITZ CASING 21 4 8 UNPACKING MOUNTING THE LIENZ CASING 21 4 9 UNPACKING MOUNTING THE MONTREUX CASING 21 4 10 CONNECTING THE APPLIANCE TO THE FLUE OUTLET 21 4 11 DRAWING COMBUSTION AIR FROM OUTSIDE 22 4 12 HANDLE 22...

Страница 3: ...io per il riscaldamento domestico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 ...

Страница 4: ...i esercizio Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 207 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 6 06 kW Potenza termica resa in ambiente Room heating output 6 06 kW P...

Страница 5: ...ico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 THERMOROSSI S P A Via Grumolo ...

Страница 6: ...pressure Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 226 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 8 53 kW Potenza termica resa in ambiente Room heating output 8 53 kW Pote...

Страница 7: ...aldamento domestico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 THERMOROSSI S ...

Страница 8: ...rking pressure Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 147 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 6 52 kW Potenza termica resa in ambiente Room heating output 6 52 k...

Страница 9: ...aldamento domestico senza acqua alimentato a ceppi di legna Residential space heating appliance without water fired by wood logs 4 Nome denominazione commerciale registrata o marchio registrato e indirizzo del fabbricante ai sensi dell articolo 11 paragrafo 5 Name registered trade name or registered trade mark and contact address of the manufacturer as required pursuant Article 11 5 THERMOROSSI S ...

Страница 10: ...orking pressure Maximum operating pressure bar Temperatura fumi a potenza termica nominale Flue gas temperature at nominal heat output T 143 C Resistenza meccanica per sopportare un camino una canna fumaria Mechanical resistance to carry a chimney flue NPD Nessuna Prestazione Determinata Potenza termica nominale Nominal heat output 8 51 kW Potenza termica resa in ambiente Room heating output 8 51 ...

Страница 11: ...zioni legislative che traspongono le seguenti Direttive 2014 30 UE ex 2004 108 CE Direttiva EMC 2014 35 UE ex 2006 95 CE Direttiva Bassa Tensione 2011 65 EU Direttiva RoHS 2 is in accordance with the following Directives 2014 30 EU Directive formerly 2004 108 EC EMC Directive 2014 35 EU Directive formerly 2006 95 EC Low Voltage Directive 2011 65 EU Directive RoHS 2 e che sono state applicate tutte...

Страница 12: ...ongono le seguenti Direttive 2014 30 UE ex 2004 108 CE Direttiva EMC 2014 35 UE ex 2006 95 CE Direttiva Bassa Tensione 2011 65 EU Direttiva RoHS 2 is in accordance with the following Directives 2014 30 EU Directive formerly 2004 108 EC EMC Directive 2014 35 EU Directive formerly 2006 95 EC Low Voltage Directive 2011 65 EU Directive RoHS 2 e che sono state applicate tutte le norme e o specifiche te...

Страница 13: ...ge can cause serious injury to persons using the appliance DAMAGE TO PROPERTY This safety symbol identifies messages or instructions that are fundamental for the generator to function well To avoid serious damage to the appliance adhere strictly to these instructions INFORMATION This symbol indicates important instructions for good functioning of the appliance If this information is not correctly ...

Страница 14: ... in this manual must be carried out when the appliance is cold Attention Warning for Swiss users Refer to the local cantonal regulations imposed by the Fire Department Mandatory signalling and safety distances and the Note concerning installation of heaters issued by the Association of Cantonal Fire Agencies VKF AEAI 1 3 TRANSPORTATION AND STORAGE TRANSPORTATION AND HANDLING The appliance body mus...

Страница 15: ...he 1st speed for the WAIR6 and at the 4th speed for the WAIR8 Important take into consideration the fact that the heatable volume is greatly influenced by the insulation of the house i e the energy class of the building and by the position of the appliance in the planimetry of the house The indicated values therefore can vary considerably The data refer to an absorption coefficient of 37 W m3 It i...

Страница 16: ...ed for less than 18 20 months as this could be the cause of malfunctions and the formation of tarry deposits that could permanently blacken the walls of the combustion chamber We recommend the use of 250 mm long wood billets load a maximum of 2 3 billets at the time and in any case do not exceed the maximum weight stated in the technical data The fuel feed intervals must not be less than those spe...

Страница 17: ...se only the handle provided to move the lever Pulling the Smoke Bypass Device upwards activates the direct bypass of the flue gases whereas pushing the Smoke Bypass Device downwards activates the normal flue gas path D Firebox door When the appliance is operating the door must remain firmly closed and airtight It must only be opened to refuel E Combustion chamber The combustion chamber is made of ...

Страница 18: ...Page 18 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Страница 19: ...ng oxygen to the appliance 4 2 UNPACKING THE APPLIANCE The appliance is supplied packaged on a pallet before positioning and installing it dismantle the appliance from the pallet as described Remove the cover and the side panels of the pallet A and also the protection panel B Figure 1 Use a screwdriver to undo the 2 screws C see Figure 2 and 3 Remove the protection panel D from the combustion cham...

Страница 20: ...Page 20 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Страница 21: ...icated chapter Legenda Key Figura Figure Il presente disegno è di proprietà esclusiva di THERMOROSSI S p A La riproduzione totale e o parziale e la divulgazione a terzi senza nostro esplicito consenso scritto verrà perseguito secondo i termini di legge in vigore Tiziano Pegoraro 27 01 2012 PIDRA 14 Scala Locazione file Data Firma Foglio Note Materiale Prodotto Sviluppo PELLET IDRA 14 KW 20 25 TEL ...

Страница 22: ...r intake to 80 mm Figure 2 Connect the air intake on the appliance to the exterior of the building with suitable piping The maximum length of the piping is 40 cm 4 12 HANDLE Your appliance is supplied with a handle for opening and closing the firebox door Figure 2 to enable you to refuel the wood and to carry out cleaning operations see dedicated paragraph When not in use the handle can be stowed ...

Страница 23: ...t smell It is recommended to ventilate the room until the paint has completely dried 5 1 LIGHTING Before using the appliance check that all the movable parts are correctly fitted Also remove any labels and stickers from the glass to avoid that permanent traces remain on the surfaces Also check that the connection to the flue outlet has been made correctly To startup the stove proceed as follows 1 ...

Страница 24: ...el fornitore prima di realizzare qualsiasi attrezzatura fornire a THERMOROSSI S p A i file tridimensionali dei particolari definitivi X IN ACCENSIONE A B RISPARMIO ENERGETICO A B POTENZA NOMINALE 6 A B POTENZA NOMINALE 8 A B WAIR6 Primary air lever Open between the first and second bars Secondary air lever Open on the 2nd bar WAIR8 Primary air lever Open on the 2nd bar Secondary air lever Open on ...

Страница 25: ... side of the appliance and the setting options are as follows 100 Front 50 Front 50 Rear 100 Rear Prescriptions for correct channelling It is prohibited to use plastic or internally corrugated pipes It is prohibited to position sections with a downward slope Reduce the number of bends as much as possible maximum 4 To ensure a good result it is obligatory to insulate the pipes Maintain a distance o...

Страница 26: ...t to the system to objects and to persons using the appliance Attention do not wet or touch the appliance with wet hands Never vacuum hot ash this could damage the vacuum device All the cleaning operations described in this manual must be carried out when the appliance is cold To clean the glass simply use a damp soft non abrasive cloth and ash The use of any other product is strictly prohibited D...

Страница 27: ...Page 27 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Страница 28: ...d when the heater is cold using a soft cloth and water The door of the combustion chamber must only be opened when the appliance has completely cooled down when it is opened it is normal for some ash to spill onto the floor ATTENTION after cleaning it is mandatory to carefully check that the combustion chamber door is firmly closed and airtight ATTENTION the generator the smoke channel and flue ou...

Страница 29: ...ection indicated above be situated at a height near floor level and they must not obstruct the correct operation of the combustion product discharge devices if this position is not possible the section of the ventilation openings must be enlarged by at least 50 7 3 SMOKE OUTLET The smoke channel the exhaust pipe chimney and flue outlet defined as the system for the evacuation of combustion product...

Страница 30: ... are also indicated in the figure below ATTENTION Wall outlets that is outlets installed on the outer front wall without the use of a chimney flue outlet flue pipe to convey the combustion products to the roof are strictly prohibited Components and accessories of a chimney Key 1 Chimney 2 Flow path 3 Smoke discharge tube 4 Thermal insulation 5 External wall 6 Outer lining 7 Flue outlet section 8 M...

Страница 31: ...e gases are discharged If you prefer to exhaust the smoke from the roof insert a union tee with inspection cap connecting brackets suitable for the height of the flue outlet flashing that crosses the roof and chimney cap to protect against bad weather conditions LEGENDA KEY COMIGNOLO E CANNA FUMARIA SECONDO NORMA UNI 10683 CHIMNEY CAP AND FLUE OUTLET ACCORDING TO UNI 10683 STANDARD Tutte le tubazi...

Страница 32: ...products which tend to accumulate along the discharge path Seal the fittings with red silicone resistant to 350 C The outer casing of the tube must be made with insulating material mineral wool ceramic fiber or use pre insulated tubing THE FLUE OUTLET MUST BE USED ONLY FOR THE APPLIANCE It must be possible to inspect and remove all the smoke tube sections for clean out purposes ATTENTION if the fl...

Страница 33: ...Page 33 Installation Use and Maintenance Guide Stove body WAIR6 WAIR6 WITH AIRBOX 1 Stove body WAIR8 WAIR8 WITH AIRBOX 1 ...

Отзывы: