background image

16

BACK TO INDEX

For more information about our products and how to contact us, please visit thermopatch.com

8. Maintenance

 

Make sure that the working cycle of the machine has ended before you start working on the machine.  
Depending on the work to be performed, the power supply or the air supply can be disconnected.
The air cylinder and other parts of the machine are virtually maintenance-free.
However, the condition is that clean and dry air is used for the heat seal machine.  
The applied water separator / pressure regulator is an extra safety.
Have your machine serviced by technically qualified personnel. Moisture and polluted air disturb the  
sustainable lubrication of the air cylinder. 

Teflon cover:
The Teflon film protecting the element must be cleaned regularly to prevent sticking of labels and patches 
or the transfer of dirt to the garments. Clean the Teflon cover with a dry, clean cloth while the machine is 
still warm. Repeat the process regularly as often as necessary. Damaged or soiled Teflon protection should 
be replaced. These are available from your Thermopatch supplier.

Rubber cushion:
Clean the still warm rubber plate with a clean, lint-free cloth. Clean it as often as necessary.  
Damaged or soiled rubber sheets must be replaced. These are available from your Thermopatch supplier.

Replacing the rubber cushion:
•  Turn off the device and allow it to cool
•  Make sure both the bottom metal plate and the rubber cushion are clean and free of grease
•  Apply SPA-0892330 silicone adhesive (with a glue comb) to the metal plate and place the rubber 
 

plate immediately with no air bubbles

•  Allow to dry overnight at room temperature under light pressure without heating.

Air filter:
The air filter, or the water separator / pressure regulator, must be checked daily and, if necessary, emptied 
by opening the cap on the underside of the filter.

Replace the fuses
Make sure that the machine is switched off and that the power cord is unplugged! Replace the T16 A fuses 
at the back of the machine. Then plug in the power cord again and the machine is ready for use again.
 

ATTENTION!

Remove the plug from the wall socket BEFORE starting maintenance or repairs.

Содержание NL-35

Страница 1: ...EN U S E R M A N U A L NL 35 v 3 ATTENTION These instructions must be made available to all persons involved in the assembly commissioning operation maintenance and repair of this product v 1 2 05 21...

Страница 2: ...over any fault or damage upon receipt of this product please contact your local Thermopatch vendor The manual has been prepared in accordance with NEN 5509 and in conformity with the Machinery Directi...

Страница 3: ...Sealing time and temperature settings 6 a Pressing time 7 b Temperature setting 7 c Presets 7 d Settings 8 List of alarms events 10 4 2 7 Error messages 11 4 3 Automatic head swing on or off 11 5 Ove...

Страница 4: ...ery of your NL 35 v 3 machine you will find the following NL 35 v 3 heat seal machine Power cord Air tube 6 mm 1 2 Warranty and product liability conditions Thermopatch points to its warranty and prod...

Страница 5: ...y 230 V alternating current with the supplied mains cable The NL 35 v 3 is grounded and equipped with two fuses type T 16 A 3 Pneumatic installation 2 In order to be able to work with the NL 35 v 3 wi...

Страница 6: ...heating platen has reached the desired temperature close the machine with the handle When the machine is closed the timer starts running At the end of the sealing time the press will open automatical...

Страница 7: ...o lower and raise the temperature respectively and then adjust it using the arrows Select the profile you wish to press Textile Rigid or DTG c Presets Pressing the Presets icon c brings up the menu sh...

Страница 8: ...gear wheel button lets you change the machine s technical aspects 1 2 3 4 5 7 6 1 Switch the sound on or off Warning sounds will still be emitted if a fault occurs 2 Choose between Celsius or Fahrenh...

Страница 9: ...mode The board will only switch to eco mode if it is on the home screen If the user leaves the press on another screen the screen is presumed to be in the process of being altered Simply touch the sc...

Страница 10: ...reached Signal not detected after 5 seconds Caused by faulty sensor lack of compressed air supply jamming mechanical etc Alarm 07 Lower pressing sensor not reached Signal not detected after 5 seconds...

Страница 11: ...ignal that can be silenced by pressing a button 4 3 Automatic head rotation on or off The automatic rotation of the press head can be switched off with a button This is on by default so that the press...

Страница 12: ...NL 35 v 3 is equipped with all mandatory safety requirements that apply according to the European guidelines for machine safety The emergency stop button As required in the guidelines for machines the...

Страница 13: ...ENTION In case of emergency press the emergency stop button ATTENTION Take care that there is enough space around the machine Cables and connections must not get pinched Although the heat radiation of...

Страница 14: ...ction voltage 230 Volt Temperature adjustable up to 250 C 1 Height opened 621 mm Width 572 mm Depth with connections 847 mm Net weight 71 kg Dimensions of press cushion 400 x 500 mm Fuses 2 x T 16A 25...

Страница 15: ...om 7 Transport and storage 7 1 Transport When the machine has to be moved Thermopatch recommends using the original packaging 7 2 Storage If the machine has to be stored Thermopatch recommends using t...

Страница 16: ...essary Damaged or soiled Teflon protection should be replaced These are available from your Thermopatch supplier Rubber cushion Clean the still warm rubber plate with a clean lint free cloth Clean it...

Страница 17: ...17 BACK TO INDEX For more information about our products and how to contact us please visit thermopatch com Open fuse box and replace fuses here Loosen the gray cap underneath and let out any debris...

Страница 18: ...ty ELECTRICAL PARTS SPA3X 028 MAIN ELECTRONICS 1 SPA27 005 MICA HEATING ELEMENT 400x500 2500W 1 SPA3X 029 TEMPERATURE PROBE 1 SPA3X 003 FUSE 5 x 20 mm T 16 A 250 V 2 PNEUMATIC PARTS SPA3X 204 CYLINDER...

Страница 19: ...ng element Check the on screen messages and refer to the section error messages page 9 The heating element overheats Problem with the probe of electronic board Check de messages on the LCD screen page...

Страница 20: ...20 BACK TO INDEX For more information about our products and how to contact us please visit thermopatch com 9 2 Electrical diagram...

Страница 21: ...AIR SUPPLY MAX 10 BAR 21 BACK TO INDEX For more information about our products and how to contact us please visit thermopatch com 9 3 Pneumatic diagram...

Страница 22: ...omponents These can be separated and returned for recycling 11 Declaration of Conformity CE and UKCA We Thermopatch BV Draaibrugweg 14 1332 Almere Netherlands Declare under our own responsability that...

Страница 23: ...indings in this document For any warranty Thermopatch BV refers to its general terms and conditions We can confirm that the machines we supply conform to CE when in standard configuration Using sealin...

Страница 24: ...Thermopatch BV Draaibrugweg 14 1332 AD Almere The Netherlands T 31 36 549 11 11 sales thermopatch nl www thermopatch com...

Отзывы: