The following conditions must be fulfilled before the system is put into operation. Turn
OFF power supply.
Check mechanical connections
Check that all components are properly connected
Check that all mechanical components are securely attached
Check whether combustion chamber (pot) is properly seated.
Check hidraulical connections
Check whether the circulation pump and the mixing valve is properly connected.
Check whether the safety equipment properly connected.
4.2
Chimney and flue gas pipes
The chimney should be calculated and constructed in accordance with the EN
13384-1 standard.
The venting of flue gas must be done in accordance with all applicable laws including
those related to dimensions of the chimney and materials used for its production. Flue
gas channel should be made of adequate materials, such as steel tubes, with various
sealing. In any case, materials that could potentially catch fire, e.g. wooden planks,
beams, cloth, should be adequately protected with non-combustible material. For the
sake of parity of dimensions, chimneys that are round in shape of the inner part should
have an advantage over the rectangular-shaped chimneys. Too small inner zone can
cause irregular flow from the stove to the top which could lead to poor stove
performance and excessive exhaust gas production that discharges the exhaust gas to
the environment. Gas flue pipe should be permanently installed and it would be good
to make safety door which would enable the cleaning of inner parts, especially the
horizontal parts. Smoke pipe should be installed fixed. It would be good to leave safety
gates that could do the Minitherm -r cleaning, especially in their horizontal parts. You
should avoid as much as possible horizontal mounting parts. Horizontal parts must
have a slope of at least 3% upwards. Length of the horizontal part should be minimal
and in any case not more than 3 meters.
ALL PARTS OF THE FLUE GASN PIPE NEED TO BE SECURED AND REPLACEABLE
IN ORDER FOR INTERNAL CLEANING. AVOID MULTIPLE HORIZONTAL
DEVIATION AND ANGLES.
The internal cross-section of the exhaust pipes should be smoth and all connections
must be hermetically sealed. Avoid as much horizontal mounting as possible.
Horizontal parts should have a slope of at least 3% upwards. The length of the
horizontal part of the saddle shall be minimum and in any case not more than 2 meters
with the possibility of cleaning and removing the accumulated ash. The connection to
the chimney should be made with a maximum of two exhaust pipes.
For stove operation, a constant negative pressure is required. At reduced power, the
flue gas temperature is low and condensation may occur. It is therefore important that
the chimney is well insulated. The flue pipes should be made of non-combustible
materials that are suitable and resistant to combustion products and their possible
condensation. In any case, the parts or zones that are flammable, must be properly
protected, such as wooden boards or beams.
FOR SMOKE PIPES, DO NOT USE METAL-FLEXIBLE CABLES. ALL PARTS
OF THE SMOKE PIPE SHOULD BE SAFE AND REMOVABLE TO CLEAN
CLEANING. AVOID HORIZONTAL DEVIATIONS.
Содержание Minitherm AQUA
Страница 2: ...2...
Страница 3: ...3...
Страница 18: ...Minitherm AQUA 18 4 3 Hydraulic schemes for connection...
Страница 22: ...Minitherm AQUA 22 5 3 Schematic representation of the menu control By pressing button SET we enter general menu...
Страница 23: ...Minitherm AQUA 23...
Страница 24: ...Minitherm AQUA 24 5 3 1 Clock adjustments Clock adjustments can be done on following way...
Страница 26: ...Minitherm AQUA 26 Flow chart 2 Flow chart 3 Flow chart 4...
Страница 38: ...Minitherm AQUA 38 BLACK OUT The stove is out of power Reset alarm and start again...
Страница 41: ...Minitherm AQUA 41 11 EU Label...
Страница 42: ...Minitherm AQUA 42...
Страница 43: ...Minitherm AQUA 43...