ThermoFisher Scientific ARL EQUINOX Series Скачать руководство пользователя страница 5

Safety

General Safety Guidelines

Before  using  your  sample  holder,  read  its  instruction  manual  completely  and  understand  it.
Please take notice of all warnings, cautions and notes to ensure the correct and safe functioning
of the instrument.
Never place the sample holder near an open flame or in an excessively hot environment. It must
not be installed in an ATEX explosive hazard area.
Never place the sample holder in locations where excessive moisture or corrosive materials are
present.
The  sample  holder  construction  provides  protection  against  the  risk  of  electrical  shock  by
grounding  the  appropriate  metal  parts.  The  protection  may  not  work  properly  unless  the  ARL
EQUINOX power cord is connected to a properly grounded socket. It is customer's responsibility
to assure that a proper ground connection is provided.
Never use flammable or corrosive fluids with this unit.
If the sample holder is used in a manner not specified by Thermo Fisher Scientific, the protection
provided by the sample holder may be impaired.
Only accessories that comply with Thermo Fisher Scientific specifications are allowed to be used
with ARL EQUINOX X-Ray diffractometers.
Transport of the sample holder should be done with extreme care.
Never operate a damaged or a leaking sample holder.
Never operate the sample holder with a damaged power cord.

Hazard Statements and Symbols

The following messages are used throughout the manuals to highlight information.

A Note message indicates the information in it requires special attention.

CAUTION!

A Caution message indicates a potentially hazardous situation that, if not avoided, may
result in moderate or minor injury. It may also be used to alert against unsafe practices.

SERVICE!

A Service message indicates that the described procedure should be performed by
qualified personnel only.

CAUTION! Do not apply the pressure higher than 2 bar inside the sample chamber of the SSCA.

Confidential, limited rights

PN AA83871 | Revision A

SSCA Sample Holder: Instruction Notice

Page

 5

Safety

Chapter|

3

3.1




3.2

Note

Содержание ARL EQUINOX Series

Страница 1: ...Thermo Scientific ARL EQUINOX Series SSCA Sample Holder Instruction Notice AA83871 A February 2022...

Страница 2: ...to the Power Supply 4 3 Setting of the Incidence Angle 5 Sample Preparation Procedure 5 1 Preparing the Sample Outside a Glove Box 5 2 Preparing the Sample Inside a Glove Box 5 3 Preparing Sample Ins...

Страница 3: ...his document is the original manual The information in this document is subject to change without notice We assume no responsibility for any errors that may appear in this document Confidential limite...

Страница 4: ...nal information contact Thermo Fisher Scientific Supplied Items Before the shipment the sample holders are tested and packed carefully However damage can oc cur during the transport If the sample hold...

Страница 5: ...not specified by Thermo Fisher Scientific the protection provided by the sample holder may be impaired Only accessories that comply with Thermo Fisher Scientific specifications are allowed to be used...

Страница 6: ...strapping of a Kapton window on a Viton O ring and by a stainless steel belt This makes the easy replacement of the window Two rapid connectors allow to connect to the gas system like vacuum pump of...

Страница 7: ...er has to be inser ted in the reference hole For more detailed information refer to the ARL EQUINOX instruction notice Connections to the Power Supply The SSCA sample holder is supplied by 12VDC The p...

Страница 8: ...in the picture below The longest line represents the incidence angle equal to 0 2 Each short line represents 2 of incidence angle 4 The medium long lines represent 10 of inci dence angle 3 Then the i...

Страница 9: ...he surface of the powder mount in order to avoid line displacement error due to height error Use a glass slide to make the surface flat and homogeneous Set the Kapton disk in the housing to make ease...

Страница 10: ...ractometer as described above If sample does not require any further preparation then proceed as described in Preparing the Sam ple Outside a Glove Box on page 9 If the sample requires a preparation s...

Страница 11: ...ing for low energy X ray it is better to replace the argon gas by heli um nitrogen or other inert acceptable gas Introduction of components inside the glove box The following figure shows the parts wh...

Страница 12: ...le holder exit from the glove box Insertion of the SSCA in the ARL EQUINOX Insert the sample holder in the sample holder mounting hole of the instrument Do not use any un necessary force The sample ho...

Страница 13: ...ing the sealing between the cover and the sample holder should be replaced if damaged No glue Window Ref 100421014 can be replaced if necessary Remove the 24 M3 screws Remove the Kapton foil Remove an...

Страница 14: ...in ON position If the problem persists contact Thermo Fisher Scientific You observe peak shift Check your sample preparation make sure that you have right amount of powder in the cup Check the alignm...

Страница 15: ...irectives EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements 2011 65 EC restriction of the use of certain hazardous sub...

Страница 16: ...ng Sample Inside a Glove Box and Gas Replacement 10 Preparing the Sample Inside a Glove Box 10 Preparing the Sample Outside a Glove Box 9 R Revision Table 3 S SSCA Sample Holder Description 5 Safety 5...

Страница 17: ...ic and its subsidiaries unless otherwise specified Learn more at thermofisher com elemental or email us at info spectrometry thermofisher com Thermo Fisher Scientific Brno s r o Vlastimila Pecha 1282...

Отзывы: