21
40.020.927 - rev. 07 - 2016
IMAC 2000 S
ENGLISH
IMAC 2000 S
40.20.927 - rev. 06 - 2011
21
English
Write down the maintenance information in table
A in the Appendix at the back of this manual.
7
SPARE PARTS
We advise you to keep spare parts in stock. See
the service manual for details.
8
TECHNICAL INFORMATION
•
For technical specifications, refer to table C
in the Appendix at the back of this manual.
The burner is
producing soot.
32
The air inlet has not been
correctly set.
Set the air inlet.
Dealer
The burner will
start, a flame has
been formed, but
the burner stops.
33
An error has occurred in the
burner relay.
Reset the thermostat. See fig. 7
(G).
User
Contact the dealer if the error is
repeated.
Dealer
The convector
heater cannot be
switched off.
34
The magnet valve or valves will
not close.
Close the valve of the fuel
supply. 8 (B).
User
Contact your dealer.
Dealer
The convector
heater stops.
35
An overheating problem has
occurred in the convector heater.
Reduce the resistance at the
outlet.
User
Reset the thermostat.
User
Contact the dealer if the error is
repeated.
Dealer
The convector
heater stops
burning. The reset
button lights up.
36
The fuel-supply line or the fuel
filter is leaking.
Check and replace if necessary. User
37
The protective grill of the air inlet
is dirty or clogged.
Clean the grill.
User
38
The heat exchanger is blocked. Clean the heat exchanger.
Dealer
The convector
heater is producing
white smoke.
39
There is air in the fuel system.
Check the fuel-supply line for
leakage.
User
Burner
malfunction: the
indicator light (red)
is on.
40
There is no fuel.
Check whether there is fuel in
the tank.
User
The photocell is dirty.
Clean the photocell.
User
The photocell is defective.
Replace the photocell.
Dealer
Fault
Cause
Solution
Action
Содержание IMAC 2000 S
Страница 60: ...60 40 020 927 rev 07 2016 IMAC 2000 S...
Страница 70: ...70 40 020 927 rev 07 2016 IMAC 2000 S...