INSTALLATION OF ACCESSORIES
9.1
Flue (fig. 9)
The convector heater has a flue connection.
1.
Slide a flue (B) over the connection (C).
2.
Place a rain cover (A) on the end of the flue.
9.2
Diameter of the flue
/i
9.3
Air hose
Hoses may be connected to the exhaust opening
of the convector heater to convey hot air
elsewhere.
/i
Contact your dealer for information about the
maximum resistance and the diameters of the
exhaust hoses, bends, manifolds and hose
clamps.
9.4
Diameters of exhaust hoses
/i
9.5
Room thermostat
Refer to the instructions of the thermostat.
10
STANDARDS AND GUIDELINES
THERMOBILE INDUSTRIES B.V., Konijnenberg
80, NL-4825 BD BREDA, the Netherlands,
declare, completely on their own responsibility,
that the product:
INDIRECT NATURAL GAS-FIRED
CONVECTOR HEATERS IMAC 2000S-G US
,
IMA 111-G US
, and
IMA 185-G US
have been designed and built according to the
National Fuel Gas Code ANSI Z223.1/NFPA 54
and the Natural Gas and Propane Installation
Code, CSA B149.1.
Netherlands, Breda,
01-02-2010
B. Posthumus
Managing Director
Caution
The flue should point upward. Do not let
the flue point sideways. An angle of 45°
is acceptable; the length of the flue
should be at least 3.5 ft.
Flue (external)
IMAC - IMA - G US
Diameter
8 inch
Caution
Check the temperature resistance of the
hose used. The maximum air
temperature of the duct is 240 °F.
Air hose
IMAC
IMA 111 IMA 185
Diameter
24 inch 20 inch 24 inch
Outlet
IMAC
IMA 111 IMA 185
Diameter
24 inch 20 inch 24 inch