6
3. Electrical Connections.
Figure Nº 3 shows a diagram that will help you connect your water heater electrically.
Figure Nº 3 Electrical Connections
Ground
Live Line 120V
Live Line 120V
Use the appropriate components depending on the model you purchased. See Table Nº 2
Table Nº2 Suitable Components for Installation
Model
Volume
(Gal)
Watts (W)
Volts
(V)
Breaker
(A)
Cord
(AWG)
Titan-9
1,8
9000
220 ~ 240
2P/40A
#8
Titan-12
1,8
12000
220 ~ 240
2P/50A
#8
Connect the power lines from the breaker to the heater with the size indicated in Table No. 2
avoid splicing wires if your situation using connectors specified for that matter.
Make sure the connections are tightly secured and that no false contacts.
To provide continued protection against the risk of electric shock, connect to properly
grounded outlets only.
IMPORTANT
Before connecting the water heater to the electrical installation ensure that
the heater is completely fill, letting the water run for 2 minutes.
Connect the breaker and so its instantaneous heater will be ready to start normal operation.
C. Operation
If you want to change the temperature of the water out the heater, remember that less flow
gives a higher temperature and more flow gives a lower temperature. Remember to be careful
with the risk of burning.