background image

INSTRUCTIONS 

 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Pierce Biotechnology 

PO Box 117 

(815) 968-0747 

thermofisher.com 

 

 

 

3747 N. Meridian Road 

Rockford, lL 61105 USA 

(815) 968-7316 fax 

 

 

Number 

Description 

89877 

Zeba Spin Desalting Columns, Micro (75µL),

 25 columns, for 2-12µL samples 

89878 

Zeba Spin Desalting Columns, Micro (75µL),

 50 columns, for 2-12µL samples 

89882 

Zeba Spin Desalting Columns, 0.5mL, 

25 columns, for 30-130µL samples 

89883 

Zeba Spin Desalting Columns, 0.5mL, 

50 columns, for 30-130µL samples 

89889 

Zeba Spin Desalting Columns, 2mL, 

5 columns, for 200-700µL samples 

89890 

Zeba Spin Desalting Columns, 2mL, 

25 columns, for 200-700µL samples 

89891 

Zeba Spin Desalting Columns, 5mL,

 5 columns, for 500-2000µL samples 

89892 

Zeba Spin Desalting Columns, 5mL,

 25 columns, for 500-2000µL samples 

89893 

Zeba Spin Desalting Columns, 10mL,

 5 columns, for 700-4000µL samples 

89894 

Zeba Spin Desalting Columns, 10mL,

 25 columns, for 700-4000µL samples 

89807 

Zeba Spin Desalting Plates, 96-well,

 2 plates 

89808 

Zeba Spin Desalting Plates, 96-well,

 4 plates 

 

 

Note: 

These products are recommended for processing compounds > 7000Da. The resin slurry is 

supplied in 0.05% sodium azide. 

 

 

Storage:

 Upon receipt store at 4

°

C. Product shipped at ambient temperature. 

 

Introduction 

The Thermo Scientific™ Zeba™ Spin Desalting Columns contain a high-performance resin that offers exceptional desalting 
or buffer-exchange for protein samples. Samples volumes between 2µL-4mL and

 

containing as low as 20µg of protein/mL 

can be processed with unsurpassed protein recovery and 

≥ 

95% retention of salts and other small molecules (< 1000Da). 

These columns require no chromatography system. The spin-column method eliminates waiting for samples to emerge by 
gravity flow and the subsequent monitoring of fractions for protein recovery. 

 

Important Product Information 

 

The Zeba Spin Desalting Columns and Plates contain a size-exclusion chromatographic resin to separate proteins from 
small molecules. As with all size exclusion-based separation, the amount of small molecule removed and protein 
recovered are affected by the nature of the molecules and volume of sample. The sample volumes recommended provide 
exceptional removal of a variety of small molecules (typically > 95% for molecules < 1000Da); however, proteins and 
small molecules often behave differently than predicted because of a variety of factors such as hydrophobicity, 
secondary structure and interactions. Therefore, some optimization of sample volume might be required to achieve 
optimal performance for each specific sample. In general, reducing the sample volume added to the column increases 
small molecule removal, and increasing sample volume maximizes protein recovery. 

 

Also available are Zeba Spin Desalting Columns and Plates with a 40K MWCO, which enable removal of salts and other 
small molecules < 2000Da and recovery of proteins and other macromolecules > 40,000Da. 

 

 

Pub. No. MAN0015751 

Pub. Part No. 2162579.1 

Rev A.0 

 

Zeba Spin Desalting Columns and Plates, 
7K MWCO 

Отзывы: