Operating Instructions | HERAcell® 150i / 240i
4
Description of the device
4
Description of the device
28
50115191 A / 08.2009
4.2 Rear view HERAcell
®
150i
Rear view
[1] Access port, Ø 42 mm
[2] Pressure compensation opening
[3] Control box with supply interface for combined gas connection
(optional) CO
2
and O
2
/N
2
without gas monitoring
[4] Condensate drain gutter
[5] Diagram: Gas connection CO
2
and O
2
/N
2
without gas monitoring
[6] O
2
/N
2
gas cylinder
[7] CO
2
gas cylinder
[8]
Secondary
CO
2
gas supply
B
with optional gas monitoring
[9]
Primary
CO
2
gas supply
A
with optional gas monitoring
[10]
Secondary
O
2
/N
2
gas supply
B
with optional gas monitoring
[11]
Primary
O
2
/N
2
gas supply
A
with optional gas monitoring
[12] Control box with supply interface for combined gas connection
(optional) CO
2
and O
2
/N
2
with gas monitoring (optional)
[13] Distributor connection for looping through the CO
2
gas supply for
up to three additional devices (independent of device type)
[14] Distributor connection for looping through the O
2
/N
2
gas supply for
up to 3 additional devices (independent of device type)
[15] Diagram: Gas connection CO
2
and O
2
/N
2
with optional gas
monitoring
Содержание Heracell 150i