Thermo Scientific DeviceLink DLH-CO2-100-RS Скачать руководство пользователя страница 1

For Research Use Only. Not for use in diagnostic procedures.

DeviceLink

 Hub

USER GUIDE

Catalog Numbers  

 DLH-HP-100-TTL , DLH-ULT-100-RS , DLH-CO2-100-RS , and DLH-CO2-100-USB

Publication Number  

 MAN0017657

Revision  

 A.0

Содержание DeviceLink DLH-CO2-100-RS

Страница 1: ...Research Use Only Not for use in diagnostic procedures DeviceLink Hub USER GUIDE Catalog Numbers DLH HP 100 TTL DLH ULT 100 RS DLH CO2 100 RS and DLH CO2 100 USB Publication Number MAN0017657 Revision...

Страница 2: ...N WITH OR ARISING FROM THIS DOCUMENT INCLUDING YOUR USE OF IT Revision history Pub No MAN0017657 Revision Date Description A 0 18 June 2018 New document Important Licensing Information These products...

Страница 3: ...10 Before first use 10 Unpack the device 10 Prepare the power supply 11 Power on and set up the DeviceLink Hub 12 Mount the DeviceLink Hub to the laboratory equipment or instrument using magnets 14 C...

Страница 4: ...mo Fisher Scientific 35 Instrument safety 35 General 35 Electrical 35 Cleaning and decontamination 36 Instrument component and accessory disposal 36 Safety and electromagnetic compatibility EMC standa...

Страница 5: ...es specified in procedures may be abbreviated in this document For the complete safety information see the Safety appendix in this document IMPORTANT Before using this product read and understand the...

Страница 6: ...ly with FDA 21CFR Part 11 for electronic records Contents Cat No Contents DLH HP 100 TTL DeviceLink Hub Remote Monitoring Module High Performance Refrigerator Freezer data cable Note For use with HP u...

Страница 7: ...r Specification Device operating electrical rating 5 1 VDC 2 5 A Category Class A Power supply Cat No T5989DV Wall mounted power adapter Input AC 90 264 VAC 50 60 Hz 0 5 A Output 5 1 VDC 2 5 A 2 pin p...

Страница 8: ...i Fi Extender dongle included up to 70 meters RSSI Wireless Network Strength 70 dBm Required materials not supplied Wi Fi enabled device phone tablet or laptop Site requirements Internet access Wi Fi...

Страница 9: ...ication Operating Temperature 0 40 C 32 104 F Relative humidity 85 non condensing Operating Environment Conditions Non corrosive Non flammable Non explosive Chapter 1 Product information Environmental...

Страница 10: ...duct packaging for damage before signing for the shipment Note Packaging damage does not denote that the product is also damaged 2 Remove the product from its shipping carton then inspect for damage 3...

Страница 11: ...supply 2 Adapter 3 Slots where adapter tracts slide 4 Adapter tracts 5 Release button The adapter should slide easily and there should be a click when the adapter is locked 3 To switch to another ada...

Страница 12: ...ible Power Supply UPS plug the power supply into the DeviceLink Hub then connect it to the UPS The UPS must be purchased separately When the DeviceLink Hub is powered on the Wi Fi hotspot is enabled u...

Страница 13: ...ent the cables from hanging freely 1 1 3 2 3 4 1 Data cable 2 Wi Fi extender dongle 3 Power cable 4 Clip 3 Plug the data cable into a USB port on the DeviceLink Hub then connect the data cable to the...

Страница 14: ...ar the laboratory equipment or instrument being monitored 1 Copy the MAC ID and serial number S N number which are on the bottom of the DeviceLink Hub You need the MAC ID and serial number during the...

Страница 15: ...uipment or instrument being monitored The magnets are on the bottom of the DeviceLink Hub 1 1 1 1 1 Magnets Chapter 2 DeviceLink Hub setup and operation Mount the DeviceLink Hub to the laboratory equi...

Страница 16: ...d to cables breaking and loss of monitoring function An Ultra Low Temperature freezer is shown in the following figures as an example Other laboratory equipment and instruments are connected in a simi...

Страница 17: ...n the previous step Note Before installing the adhesive mounts ensure that the cables can reach the appropriate plugs a Find a location on the laboratory equipment or instrument to mount the DeviceLin...

Страница 18: ...ly Connect the DeviceLink Hub to a network and link to Thermo Fisher Cloud 1 Connect the DeviceLink Hub to a network a Open the Wi Fi settings menu on your Wi Fi enabled device phone tablet or laptop...

Страница 19: ...Note If you have previously used your device phone tablet or laptop to connect the DeviceLink Hub your device may remember the password and may not require you to enter a password Chapter 2 DeviceLink...

Страница 20: ...i Fi or Ethernet If you are going to connect the DeviceLink Hub to the internet by Ethernet skip the Wi Fi configuration fields in step 4 The SSID and Network Password fields are blocked out IMPORTANT...

Страница 21: ...s Items pane enter the appropriate information for each field then click Configure DLH Chapter 2 DeviceLink Hub setup and operation Connect the DeviceLink Hub to a network and link to Thermo Fisher Cl...

Страница 22: ...SSID field Instrument type Select the laboratory equipment or instrument being monitored then click Done Thermo Fisher Cloud User Enter the username of the Thermo Fisher Cloud account Thermo Fisher Cl...

Страница 23: ...er Connect application on the Thermo Fisher Cloud 2 In the Thermo Fisher Connect home screen in the left menu bar click 3 To view sensor data and alerts select the laboratory equipment or instrument f...

Страница 24: ...then repeats the pattern Repeat the Connect the DeviceLink Hub to a network and link to Thermo Fisher Cloud on page 18 procedure Wrong TFC credentials User entered the wrong Thermo Fisher Cloud crede...

Страница 25: ...boratory equipment or instrument being monitored and affiliated Thermo Fisher Cloud account cannot be changed 1 Open a web browser on your device then enter the following IP address https dlh thermofi...

Страница 26: ...uipment or instrument being monitored or the affiliated Thermo Fisher Cloud account 1 Power off then power on the DeviceLink Hub by unplugging and plugging in the power supply 2 Connect the DeviceLink...

Страница 27: ...with the letters DLH followed by the last 8 alphanumeric characters from the serial number on the label which is on the bottom of the DeviceLink Hub See the figure in substep 2c Appendix B Supplement...

Страница 28: ...MAC ID 2 Serial number S N Note If you have previously used your device phone tablet or laptop to connect the DeviceLink Hub your device may remember the password and may not require you to enter a p...

Страница 29: ...tablet or laptop then enter the following web address https dlh thermofisher com Note You must enter https not http The DLH Configuration window opens Appendix B Supplemental procedures Reset the Devi...

Страница 30: ...4 Click Factory Reset Appendix B Supplemental procedures Reset the DeviceLink Hub B 30 DeviceLink Hub User Guide...

Страница 31: ...5 Click Confirm Factory Reset A confirmation message appears Appendix B Supplemental procedures Reset the DeviceLink Hub B DeviceLink Hub User Guide 31...

Страница 32: ...cument Symbols on this instrument Symbols may be found on the instrument to warn against potential hazards or convey important safety information In this document the hazard symbol is used along with...

Страница 33: ...rdinances for proper disposal provision and contact customer service for information about responsible disposal options Ne pas liminer ce produit avec les d chets usuels non soumis au tri s lectif MIS...

Страница 34: ...e the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio...

Страница 35: ...ot designed or built by Thermo Fisher Scientific Consult the manufacturer s documentation for the information needed for the safe use of these products Instrument safety CAUTION Do not remove instrume...

Страница 36: ...acturer users should confirm with the manufacturer that the proposed method will not damage the equipment To minimize negative environmental impact from disposal of electronic waste do not dispose of...

Страница 37: ...on Directive_2012_19_EU European Union WEEE Directive Waste electrical and electronic equipment Directive 2011 65 EU European Union RoHS Directive Restriction of hazardous substances in electrical and...

Страница 38: ...with our standard warranty as described in the Terms and Conditions of Sale applicable to your purchase of this product Unless otherwise agreed to in writing Thermo Scientific warrants that the produc...

Страница 39: ......

Страница 40: ...thermofisher com support thermofisher com askaquestion thermofisher com 18 June 2018...

Отзывы: