Keypad Display Menu Tree of DensityPRO Gauges
Thermo Scientific
DensityPRO User Manual
A-17
MAIN
MENU
COMMUNICATION
SETUP
SYSTEM
CONTROL
SYSTEM
STATUS
Mode/Fault
Alarm
Setup
MORE…
MAIN
MENU
COMMANDS
PHYSICAL
I/O
DETECTOR
PREV…
SELECT
DETECTOR
DET1
BACK
NEXT
BACK
NEXT
BACK
NEXT
DETECTOR
CONFIG
SETTING
MEASURMNT
&
APPLICATION
DETECTOR
SETTING
SETUP
DETECTOR
SETUP
DYNAMIC
TRACKING
X
‐
RAY
TIME
DYNAMIC
TRACKING
DYNAMIC
TRACKING
B
ENABLE:
Enabled
TIME
(SEC):
16
DYNAMIC
TRACKING
THRESHOLD%
B
5.300000
BACK
NEXT
BACK
NEXT
BACK
NEXT
BACK
EDIT
NEXT
DETECTOR
SETUP
DYNAMIC
TRACKING
X
‐
RAY
TIME
X
‐
RAY
X
‐
RAY
THRESHOLD
ENABLE
B
Disabled
X
‐
RAY
SAFEGUARD
THRESHOLD
B
0.200000
X
‐
RAY
X
‐
RAY
THRESHOLD
MIN
HOLD
TIME
B
20
X
‐
RAY
THRESHOLD
MAX
HOLD
TIME
B
300
BACK
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
DETECTOR
SETUP
DYNAMIC
TRACKING
X
‐
RAY
TIME
TIME
DENSITY
TIME
CONSTANT
B
(SEC):
128
FLOW
TIME
CONSTANT
B
(SEC):
1
BACK
NEXT
BACK
EDIT
NEXT
DETECTOR
CONFIG
SETTING
MEASURMNT
&
APPLICATION
APPLICATION
SELECT
SELECT
APPLICATION
NUMBER
B
1
APPLICATION
SELECT
SELECT
TYPE
OF
APP#X
B
DENSITY
DENSITY
APP
SUBTYPE
SELECT
DENISTY
APP
SUBTYPE
B
GENERAL
BACK
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
DENS
MEASURE
SETUP
SETUP
STANDARDIZATION
GAUGE
CALIBRATION
MEASUREMENT
DATA
TOTALS
MORE…
SETUP
DENSITY
SETUP
INPUT
CONFIGURATION
TEMP
COMPENSATION
Additional
Measurement
SOURCE
SETTING
SOURCE
HEAD
B
5201
sou
ISOTOPE
B
Cs137
MATERIAL
TYPE
B
Slurry
GRAVITY/ATTENUATION
DENSITY
(g/cc)
B
CARRIER:
1.000000
B
SOLID:
2.650000
ATTENUATION
(cm2/g)
B
CARRIER:
0.086000
B
SOLID:
0.077000
MEASUREMENT/UNITS
PRIMARY
MEASUREMENT
B
Density
DENSITY
UNIT
(PRIMARY)
B
g/cc
#
DECIMAL
PLACE
MEA
#1
B
2
BACK
NEXT
BACK
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
MEASUREMENT/UNITS
SOLUTION
TYPE
B
Suc
0
–
10
PIPE
UNIT:
in
PIPE
INSIDE
DIAMETER
B
10.00000
POLY
COEFS
SOLUTION
POLY
A
COEFF
B
1.000000
SOLUTION
POLY
B
COEFF
B
1.000000
POLY
COEFS
SOLUTION
POLY
C
COEFF
B
1.000000
SOLUTION
POLY
D
COEFF
B
1.000000
BACK
EDIT
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
SETUP
DENSITY
SETUP
INPUT
CONFIGURATION
TEMP
COMPENSATION
Additional
Measurement
INPUT
CONFIGURATION
INPUT
UNIT
INPUT
CONFIGURATION
DENISTY
INPUT
B
Not
Used
TEMPERATURE
INPUT
B
Not
Used
INPUT
CONFIGURATION
PRESSURE
INPUT
B
Not
Used
FLOW
INPUT
B
Not
Used
BACK
NEXT
BACK
NEXT
BACK
EDIT
NEXT
BACK
EDIT
NEXT
Figure
A-17.
Detector (Sheet 1 of 4)
Содержание DensityPRO NAI Series
Страница 2: ......
Страница 4: ......
Страница 6: ...This page intentionally left blank ...
Страница 8: ...This page intentionally left blank ...
Страница 14: ...xiv DensityPRO User Manual Thermo Scientific This page intentionally left blank ...
Страница 22: ...A xxii DensityPRO User Manual Thermo Scientific Quick Setup This page intentionally left blank ...
Страница 124: ...Operation Application Screens 4 72 DensityPRO User Manual Thermo Scientific Figure 4 39 High and Low Alarms ...
Страница 134: ......
Страница 158: ......
Страница 195: ......