background image

 

 

       

                   

 

                    

 

 

 

 

 

       

 

 

 

 

 

Safety Information

 

Your satisfaction and safety are important to 

Thermo

 Scientific and a complete understanding of this unit is

 

necessary to attain these objectives.

 

As the ultimate user of this apparatus, it is your responsibility to understand its proper function and operational

 

characteristics. This 

 

instruction 

 

manual 

 

should 

 

be thoroughly read and all 

 

operators given 

 

adequate 

 

training

 

before attempting to place this unit in service. Awareness of the stated cautions and warnings, and compliance

 

with recommended operating parameters – together with maintenance requirements – are important for safe and

 

satisfactory operation. The unit should be used for its intended application; alterations or modifications will void

 

the Warranty.

 

This  product  is  not  intended,  nor  can  it  be  used,  as  a  sterile  or  patient  connected  device.  In  addition,  

this apparatus  is  not  designed  for  use  in  Class  I,  II  or  III  locations  as  defined  by  the  US  National  

Electrical  Code, unless otherwise noted.

Alert Signals

ON

OFF 

Safety Alert 

Important   operating   instructions.   To   reduce   the   risk   of   injury   or   poor

performance   of   the   unit   read   the   user   manual   before   putting   the

equipment into operation. 

WARNING 

Indicates an immediately hazardous situation, which if not avoided, will

result in death or serious injury. 

CAUTION 

Indicates an immediately hazardous situation, which if not avoided, may 

result in minor to moderate injury.

(No Symbol)

CAUTION 

(Without  Safety Alert  Symbol)  indicates  a  situation  that  may  result  in

property damage. 

Shock Hazard 

Use of this equipment involves power supplies which convert line voltage

to low voltage power. Do not modify or use power supplies other than

OEM equipment. Connection of the power supply may require a properly

grounded receptacle. Potential for electrical shock or equipment damage

exists if precautions are not followed. 

Frost bite/ Low 

Temperature 

Avoid contact with cold freezer surfaces potential for cold burns or skin

sticking to cold surfaces. 

3

Содержание 02LREETSA

Страница 1: ...Installation and Operation Manual Thermo Scientific General Purpose Flammable Storage and Explosion Proof Freezers...

Страница 2: ...2016 Thermo Fisher Scientific All rights reserved...

Страница 3: ...General Purpose Flammable Material Storage and Explosion Proof Freezers Explosion Proof 05EFEETSA Flammable Material Storage 05FFEETSA General Purpose 05LFEETSA 02LREETSA...

Страница 4: ...d Installation 13 Shipping Carton 13 Unpacking 13 Location 13 Clearance 13 Electrical 14 Be Advised 14 How to Seal Junction Box Conduit with Fiber and Sealing Compound to Help Protect Against Explosio...

Страница 5: ...s I II or III locations as defined by the US National Electrical Code unless otherwise noted Alert Signals ON OFF Safety Alert Important operating instructions To reduce the risk of injury or poor per...

Страница 6: ...refrigerator or freezer Take off doors Leave the shelves in the place so that children may not easily climb inside If the equipment is used in a manner not specified by the manufacturer the protection...

Страница 7: ...in storage is still required Store only corrosive reagents samples which truly need reduced temperature storage Flammable corrosive materials require Flammable Material Storage or Explosion Proof mod...

Страница 8: ...d determined to remain below the flash point of materials found in Class I Groups C and D All models have heavy gauge rigid steel construction with a durable enamel finish Interiors have epoxy enamel...

Страница 9: ...elves Model Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05EFEETSA 29 5 x 18 63 x 19 74 9 x 47 32 x 48 2 cm 5 0 33 13 x 21 38 x 30 25 84 15 x...

Страница 10: ...hazardous materials inside the unit These units are ideal for storing cyclopropane ethyl ether ethylene acetone alcohol benzene butane gasoline hexane lacquer solvent vapors naphtha natural gas or pr...

Страница 11: ...oor shelves Model Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05FFEETSA 29 5 x 18 63 x 19 74 9 x 47 32 x 48 2 cm 5 0 33 13 x 21 38 x 29 5 84...

Страница 12: ...ical biological materials may require alarm monitoring back up and temperature performance features The need to add these features should be determined by your industrial hygienist or safety officer T...

Страница 13: ...or shelves Model Freezer Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 05LFEETSA 29 5 x 18 63 x 19 74 9 x 47 32 x 48 2 cm 5 0 33 13 x 21 38 x 25 75 84...

Страница 14: ...ator Chamber Dimensions H x W x D inches cm Total Vol Cu Ft Exterior Dimensions H x W x D inches cm 02LREETSA 15 5 x 16 x 14 39 37 x 40 64 x 35 56 cm 1 8 19 0 x 18 63 x 17 25 48 26 x 47 32 x 43 81 cm...

Страница 15: ...unit has been received Do not discard packing materials until all is accounted for The following items are included in the shipment Refrigerator Freezer Operation Manual Inspection Tag Location Place...

Страница 16: ...ted to its own individual outlet Be Advised WARNING UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE OR FLAMMABLE ATMOSPHERES DO NOT USE IN THE PRESENCE OF FLAMMABLE OR COMBUSTIBLE MATERIALS OR EX...

Страница 17: ...vent the very real threat of gas entering the junction box and a resulting serious explosion After the unit wires have been pulled through the vertical conduit the following procedure is required Turn...

Страница 18: ...terial COMPLETELY SURROUNDS THE WIRING from the top to the bottom completely blocking this end of the vertical conduit Insert fiber rope material down into horizontal conduit opening Pressing down fir...

Страница 19: ...l not to trap air bubbles Immediately wipe off any spilled sealing compound Screw conduit domed cover back onto conduit opening NOTE INITIAL SETUP OF SEALING COMPOUND WILL OCCUR IN APPROXIMATELY 30 MI...

Страница 20: ...oduct is intended for use indoors only POLLUTION DEGREE INSTALLATION CATEGORY ALTITUDE HUMIDITY ELECTRICAL SUPPLY VOLTAGE TOLERANCE AMBIENT TEMPERATURE RANGE PRODUCT USAGE Refer to IEC 664 1 Temperatu...

Страница 21: ...any use not Do Caution coil cooling the puncturing of danger real very the of because surfaces refrigerator on and frost ice remove to scraper or blade instrument sharp any use not Do Caution Materia...

Страница 22: ...ted to 1 4 defrost Keep containers covered when possible to reduce moisture buildup Set operating temperature no colder than necessary for the items being refrigerated Safety Tips After a unit is in o...

Страница 23: ...performed by a qualified service representative Cleaning of Units Turn off the freezer Wash interior liner with a solution of two tablespoons of baking soda and a quart of warm water Then rinse and w...

Страница 24: ...is defrost unit A leak around the door gasket will allow cold air to escape This causes unit to work harder than necessary to maintain cold temperatures Re seat or replace the gasket if worn If you h...

Страница 25: ...replacement parts information and pricing please call the Customer Service Department at 1 800 438 4851 and have the unit s model serial and code numbers available This information is located on data...

Страница 26: ...ientific dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer c...

Страница 27: ...sungfallen finden Sie unter www thermo com Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WE...

Страница 28: ...ct by a party other than the manufacturer or its duly authorized service representative ii misuse including use inconsistent with written operating instructions for the product mishandling contaminati...

Страница 29: ...can be found on the dataplate attached to the equipment If available please provide the date purchased the source of purchase manufacturer or specific agent rep organization and purchase order number...

Страница 30: ...Thermo Fisher Scientific Inc 275 Aiken Road Asheville NC 28804 United States www thermofisher com 327342H01 Rev F...

Отзывы: