I.  SAFETY SECTION 
 
This  page  contains  various  warnings  and  cautions  found  throughout  the  Oil  Furnace 
Manual. Please read and comply with the statements below.
 
 
 

c

WARNING AND CAUTIONS: 

 

c

WARNING: This furnace is not to be used as a construction heater. See Page 1. 

 

c

  CAUTION  MUST  BE  TAKEN  NOT  TO  EXCEED  90°  ROTATION  (OF  THE  FLUE 

ELBOW) COUNTERCLOCKWISE OR RIGHT FROM THE VERTICAL POSITION. 
See Page 2.
 
 

c

WARNING:  The predetermined  limit location on this oil fired furnace has been tested 

and  approved  by  Thermo  Products,  LLC.  Any  attempt  to  relocate  this  safety  control  or 
replace  this  safety  control  with  a  control  that  is  not  approved,  or  is  incompatible,  may 
result in personal injury, substantial property damage or death.  See Page 5. 
 

c

WARNING:  THE  HEAT  EXCHANGER  MUST  BE  CLEANED  BY  A  QUALIFIED 

SERVICE  PERSON. See Page 8. 
 

c

CAUTION: DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF! See Page 9. 

 

c

WARNING: The area around the furnace should be kept free and clear of combustible 

liquids and  material, especially papers and rags. See Page 9. 
 

c

WARNING: NEVER burn garbage or refuse in your furnace. Never try to ignite oil by 

tossing burning papers or other material into your furnace. See Page 9. 
 

c

WARNING: This oil furnace is designed to burn No. 1 or No. 2 distillate fuel oil. NEVER 

USE GASOLINE OR A MIXTURE OF OIL AND GASOLINE. See Page 9. 

 

c

CAUTION:  DO NOT ATTEMPT TO START THE BURNER WHEN: 

1. Excess oil has accumulated, 
2. The furnace is full of vapors  

 3. The combustion chamber is very hot. 
 IF ONE OR MORE OF THESE CONDITIONS EXIST, CONTACT A QUALIFIED 
SERVICE PERSON. See Page 9. 
 

Содержание Spirit VHF-ABE

Страница 1: ...nce Improper installation adjustment alteration service or maintenance can cause a fire or explosion resulting in property damage personal injury or loss of life For assistance or additional informati...

Страница 2: ...ry substantial property damage or death See Page 5 cWARNING THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED SERVICE PERSON See Page 8 cCAUTION DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF See Page 9 cWAR...

Страница 3: ...RETURN AIRFLOW AND AIR TEMPERATURE 3 D FILTERS MOUNTED EXTERNAL TO FURNACE 4 E LIMIT POSITION AND LOCATION 5 F BURNER INSTALLATION 6 G BURNER SPECIFICATIONS AND APPLICATIONS 7 H HEAT EXCHANGER CLEANI...

Страница 4: ...located or protected to avoid physical damage by vehicles cWARNING This furnace is not to be used as a construction heater 5 Listed below are definitions of COMBUSTIBLE MATERIAL and NON COMBUSTIBLE MA...

Страница 5: ...power venter manufacturer to design and assemble a satisfactory power vent system A VENTING NOTE On the VHF A it is possible to rotate the flue elbow which is factory installed for vertical discharge...

Страница 6: ...tioning cooling the furnace should be installed parallel with or on the upstream side of the evaporator coil to avoid condensation in the furnace heat exchanger If the cooling unit is installed with a...

Страница 7: ...essary to cut the return air opening in the side or rear casing depending upon the needs of the specific installation The filter rack provided with the furnace refer to Fig 2 will serve as a template...

Страница 8: ...ange of the filter rack Connect the return air plenum to the filter rack and slide the filter into place Dimensions for adapting the return air plenum to the filter rack are provided See Fig 2 E LIMIT...

Страница 9: ...ig 4 This retainer secures the chamber during shipping and helps to maintain insertion depth DO NOT remove this retainer when installing burner Fig 4 Typical location of the overfire air tap and compo...

Страница 10: ...CONE FOR EXAMPLE A NOZZLE RATED AT 0 65 GPH 100 PSIG THAT PROVIDES AN 80 SPRAY ANGLE AND A HOLLOW SPRAY PATTERN WOULD BE ABBREVIATED IN THE TABLE AS 0 65 X 80 A For more specific burner information c...

Страница 11: ...With access to the inside of the heat exchanger through the burner area clean out openings and vent pipe connection it is possible to use a long flexible wire brush and an industrial type vacuum clean...

Страница 12: ...discoloration of materials and damage from rust or corrosion FLUE PIPE VENT PIPE OR CONNECTOR The furnace vent pipe should be inspected for signs of rust corrosion pitting or holes in pipe and leakage...

Страница 13: ...ystem and home cWARNING To avoid injury from moving parts hot surfaces or electrical shock shut off the power to the furnace before removing any furnace access doors to service the air filters The fil...

Страница 14: ...MASONRY CHIMNEY W METAL LINER FUEL LINE FILTER DRAFT CONTROL COMBUSTION TESTS Operate burner at least 10 minutes before CO2 in stack pipe INITIAL SERVICE SERVICE SERVICE INSTALLATION Draft Over fire D...

Страница 15: ...All installations and services must be performed by qualified service personnel 12 APPENDIX A Replacement Parts List...

Страница 16: ...All installations and services must be performed by qualified service personnel 13...

Страница 17: ...All installations and services must be performed by qualified service personnel 14...

Страница 18: ...All installations and services must be performed by qualified service personnel 15...

Страница 19: ...All installations and services must be performed by qualified service personnel 16 APPENDIX B Wiring Diagrams BLOWER SPEED TAPS COOL A C Tap HEAT Heating Tap LOW Constant air or Dehumifier...

Страница 20: ...All installations and services must be performed by qualified service personnel 17...

Отзывы: