Operating Instructions for Premium HMI Control Panel
54
Figure 73: Defrost Display
Terminating a Defrost Cycle
The defrost cycle terminates automatically when
the coil temperature is greater than or equal to 52
F (11 C) or the defrost timer expires. Defrost can
also be terminated by turning the unit off and back
on.
Selecting High Speed Lockout
Mode (If Enabled)
High speed operation can be locked out in noise
sensitive areas if required.
NOTE: High Speed Lockout Enable must be set
to [Enabled] in the Guarded
Access/Programmable Features Menu or this
feature will not be available.
IMPORTANT: HIGH SPEED LOCKOUT
TIMEOUT: If High Speed Lockout Mode is
selected, the High Speed Inhibit Timeout feature
may be set to return the unit to normal operation
after a set time period has expired. This prevents
extended operation with high speed operation
locked out. The time period may be from 15
minutes to 2 hours. If the time period is set and
is exceeded the unit will return to normal
operation, with high speed operation allowed. If
this occurs, the message HIGH SPEED
LOCKOUT ACTIVE at the top of the display will
disappear. If necessary to return to High Speed
Lockout Mode, press the High Speed Lockout
Key again.
The High Speed Lockout Key is a toggle. If high
speed is currently allowed, then pressing the High
Speed Lockout Key will disable high speed
operation. Pressing the High Speed Lockout Key
again will allow high speed operation. To change
the setting, press the High Speed Lockout key as
shown below.
Figure 74: High Speed Lockout Key
The display will briefly show [PROGRAMMING
HIGH SPEED LOCKOUT - PLEASE WAIT].
Figure 75: PROGRAMMING HIGH SPEED
LOCKOUT - PLEASE WAIT
The change is confirmed by briefly displaying
[HIGH SPEED LOCKOUT ACTIVE] or [HIGH
SPEED LOCKOUT INACTIVE].
Figure 76: High Speed Lockout Display
The display will then return to the Standard
Display. If High Speed Lockout is turned on, the
message HIGH SPEED LOCKOUT ACTIVE will
be shown at the top of the display.
Figure 77: Standard Display, High Speed Lockout
Active
Pressing the High Speed Lockout key again will
turn the feature off.
Содержание T-1080S
Страница 102: ...Engine Maintenance 101 Figure 182 Fuel and Oil System Components ...
Страница 182: ...Index 181 Unit Options 23 W wiring 79 wiring diagrams index 182 ...
Страница 184: ...183 Schematic Diagram Page 1 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 185: ...184 Schematic Diagram Page 2 of 2 RELEASED 06 Jul 2015 13 52 47 GMT 7 ...
Страница 186: ...185 Wiring Diagram Page 1 of 5 ...
Страница 187: ...186 Wiring Diagram Page 2 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 188: ...187 Wiring Diagram Page 3 of 5 ...
Страница 189: ...188 Wiring Diagram Page 4 of 5 RELEASED 06 Jul 2015 13 52 47 GMT ...
Страница 190: ...189 Wiring Diagram Page 5 of 5 ...