SPECTRUM™ TS Operation
73
Figure 94: Programming Test Pretrip Display
The Pretrip Test display appears. The top line of
the display indicates the unit is performing the
non-running Pretrip Test. Test progress is
measured by the number of tests completed out of
a total of 26. In the example below the unit is
performing Test 1 of 26, Sensor Check. The soft
keys may be used during the Pretrip Test to select
the Hourmeter, Gauge or Sensor menus.
Figure 95: Selecting Menus
When all tests are complete, the results are
reported as PASS, CHECK or FAIL. If the results
are CHECK or FAIL, the accompanying alarm
codes will direct the technician to the cause of the
problem.
When the non-running test are complete the unit
will start automatically and continue with the
Running Pretrip Test. In the example shown
below the unit is in the Running Pretrip and is
performing Test 21 of 26, Zone 1 Cool test.
Figure 96: Zone 1 Cool Test
If the Pretrip Test results are CHECK or FAIL the
problem should be diagnosed and corrected before
the unit is released for service.
To stop a Pretrip Test at any time turn the unit off.
This will generate Alarm Code 28 Pretrip Abort.
Other alarm codes may also be generated. This is
normal when the Pretrip test is halted before
completion.
Figure 97: Pretrip Pass Display
Selecting Diesel or Electric
Operation
The Diesel or Electric Display allows the operator
to manually select diesel mode operation. The unit
can also be programmed to automatically select
electric mode operation when standby power is
available and diesel mode operation if standby
power fails or is removed. If the unit is
programmed to switch automatically from diesel
to electric and electric to diesel these screens do
not appear.
Factory units are programmed to
automatically switch to electric mode when
standby power becomes available. The unit
must be switched to diesel power manually as
programmed from factory.
If the unit has standby power available and is
turned on, the electric standby run screen will
appear after the standard screen. The new mode is
then confirmed for 10 seconds.
.
Figure 98: Electric Standby Display
AJA1157
AJA1266
AJA1267
AJA1159
AJA1164
Содержание SPECTRUM TS 30 SR NAD
Страница 4: ...4 ...
Страница 10: ...Table of Contents 10 ...
Страница 20: ...Safety Precautions 20 ...
Страница 51: ...Unit Description 51 Figure 19 Front View Figure 20 Back View AJA1350 AJA1500 ...
Страница 52: ...Unit Description 52 1 On Off Switch Figure 21 Side View 1 ...
Страница 60: ...Unit Description 60 ...
Страница 80: ...SPECTRUM TS Operation 80 ...
Страница 90: ...Electrical Maintenance 90 ...
Страница 100: ...Engine Maintenance 100 Figure 130 Early TK 3 95 Fuel and Oil System Components ...
Страница 102: ...Engine Maintenance 102 Figure 131 Late TK 3 95 Fuel and Oil System Components ...
Страница 104: ...Engine Maintenance 104 Figure 132 TK376 Fuel and Oil System Components ...
Страница 136: ...Refrigeration Maintenance 136 ...
Страница 156: ...Hilliard Clutch Maintenance 156 ...
Страница 158: ...Structural Maintenance 158 ...
Страница 168: ...Remote Evaporator Specifications 168 ...
Страница 170: ...Remote Evaporator Maintenance Inspection Schedule 170 ...
Страница 176: ...Remote Evaporator Electrical Maintenance 176 ...
Страница 180: ...Remote Evaporator Refrigeration Service Operations 180 ...
Страница 182: ...Remote Evaporator Structural Maintenance 182 ...
Страница 184: ...Remote Evaporator System Diagnosis 184 ...
Страница 188: ...Wiring and Schematic Diagrams Index 188 ...
Страница 189: ...189 Wiring Diagram Page 1 of 4 ...
Страница 190: ...190 Wiring Diagram Page 2 of 4 ...
Страница 191: ...191 Wiring Diagram Page 3 of 4 ...
Страница 192: ...192 Wiring Diagram Page 4 of 4 ...
Страница 193: ...193 Schematic Diagram Page 1 of 3 ...
Страница 194: ...194 Schematic Diagram Page 2 of 3 ...
Страница 195: ...195 Schematic Diagram Page 3 of 3 ...
Страница 196: ...196 ...