Refrigeration Service Operations
113
5. Pressurize the refrigeration system and test for
leaks.
6. If no leaks are found, evacuate the system.
7. Recharge the unit with proper refrigerant and
check the compressor oil.
Bypass Check Valve
Removal
1. Pump down the low side and equalize the
pressure to slightly positive.
2. Close the bypass service valve.
3. Unsolder the bypass check valve line from the
bypass check valve. Use a heat sink on the
bypass check valve.
4. Unsolder and remove the bypass check valve
from the receiver tank. Use a heat sink on the
bypass check valve.
Installation
1. Solder the bypass check valve onto the
receiver tank. Use a heat sink on the bypass
check valve.
2. Solder the bypass check valve line to the
bypass check valve. Use a heat sink on the
bypass check valve.
3. Pressurize the low side and test for leaks. If no
leaks are found, evacuate the system.
4. Open the bypass service valve and place the
unit in operation.
Receiver Tank
Removal
1. Recover the refrigerant charge.
2. Unsolder the inlet, outlet, and bypass check
valve lines from the receiver tank. Use a heat
sink on the bypass check valve.
3. Unsolder and remove the bypass check valve
from the receiver tank. Use a heat sink on the
bypass check valve.
4. Remove the high pressure relief valve from
the receiver tank.
5. Unbolt the mounting brackets and remove the
receiver tank from the unit.
Installation
1. Install the high pressure relief valve in the
receiver tank.
2. Solder the bypass check valve onto the
receiver tank. Use a heat sink on the bypass
check valve.
3. Place the receiver tank in the unit and install
the mounting bolts and nuts loosely. Position
the receiver tank so that the sight glass is
clearly visible through the viewing hole in the
mounting bracket.
4. Solder the inlet, outlet, and bypass check
valve lines to the receiver tank. Use a heat
sink on the bypass check valve.
5. Tighten the receiver tank mounting hardware
securely.
6. Pressurize the refrigeration system and check
for leaks. If no leaks are found, evacuate the
system.
7. Recharge the unit with proper refrigerant.
Filter Drier
Removal
1. Pump down the low side and equalize the
pressure to slightly positive.
2. Disconnect the nuts at the ends of the drier.
3. Loosen the mounting hardware and remove
the drier.
Installation
1. Place the new O-rings in the ORS fittings on
the ends of the drier.
2. Install the new drier and tighten the mounting
hardware.
3. Install and tighten the inlet nut. Hold the drier
with a back-up wrench on the hex behind the
inlet fitting.
4. Release a small amount of refrigerant to purge
the air through the drier. Then tighten the
outlet nut.
Содержание SB-210
Страница 4: ...4 ...
Страница 12: ...List of Figures 12 ...
Страница 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Страница 32: ...Unit Description 32 1 Defrost Damper 2 X430L Compressor 3 TK 486 Engine Figure 7 Back View 2 3 1 AJA1930 ...
Страница 36: ...Unit Description 36 ...
Страница 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Страница 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Страница 101: ...Engine Maintenance 101 ...
Страница 102: ...Engine Maintenance 102 ...
Страница 140: ...Electric Standby Diagnosis 140 ...
Страница 150: ...Index 150 ...
Страница 152: ...Wiring Diagram Index 152 ...
Страница 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Страница 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Страница 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Страница 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Страница 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Страница 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Страница 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...