Refrigeration Service Operations
107
High Pressure Cutout Switch
Removal
1. Front seat the three-way valve bypass check
valve
2. Start the unit and pump down the low side.
3. Stop the unit.
4. Shift the unit into heat using the relay board
test.
5. Disconnect the wires and remove the high
pressure cutout switch from the discharge
tube.
Installation
1. Apply a refrigerant Loctite
TM
to the threads of
the high pressure cutout switch.
2. Install and tighten high pressure cutout switch
and reconnect the wires.
3. Pressurize the refrigeration system and test for
leaks. If no leaks are found, evacuate the
system.
4. Open (back seat) the three-way valve bypass
check valve.
High Pressure Relief Valve
Removal
1. Remove the refrigerant charge.
2. Unscrew and remove the high pressure relief
valve.
Installation
1. Apply a refrigerant Loctite
TM
to the threads of
the high pressure relief valve.
2. Install and tighten the high pressure relief
valve.
3. Pressurize the refrigeration system and test for
leaks. If no leaks are found, evacuate the
system.
4. Recharge the unit with refrigerant and check
the compressor oil.
Pilot Solenoid
Removal
1. Recover refrigerant from the unit.
2. Disconnect the lines to the solenoid and
immediately cap to prevent moisture and air
from entering the system.
NOTE: The lines from the three-way valve to
the pilot solenoid will leak refrigerant at a
high velocity and should be capped.
3. Disconnect the electrical wires and remove the
pilot solenoid.
Installation
1. Replace the pilot solenoid in the unit.
2. Remove the caps from the lines and connect
lines to the pilot solenoid. Connect line from
the three-way valve first. Connect wires to the
valve.
3. Evacuate and charge the unit with refrigerant.
4. Open (back seat) the three-way valve bypass
check valve.
5. Check for leaks.
Receiver Tank
Removal
1. Remove the refrigerant charge.
2. Unsolder the inlet tube from the receiver tank.
3. Unsolder the filter drier line from the receiver
tank outlet tube.
4. Unbolt the mounting brackets and remove the
receiver tank from the unit.
Installation
1. Place the receiver tank in the unit and install
the mounting bolts and nuts loosely. Position
the receiver tank so the sight glass is clearly
visible and the outlet tube lines up.
2. Solder the inlet tube to the receiver tank.
Содержание 919180
Страница 4: ...4...
Страница 10: ...Table of Contents 10...
Страница 32: ...Unit Description 32 Unit Photographs Figure 3 Front View Figure 4 Back View AJA584 AJA585...
Страница 33: ...Unit Description 33 Figure 5 Left Side View Figure 6 Right Side View AJA586 AJA58...
Страница 35: ...Unit Description 35 Figure 8 North American Power Receptacle Box AJA58...
Страница 38: ...Unit Description 38...
Страница 58: ...Electrical Maintenance 58...
Страница 66: ...Engine Maintenance 66 Figure 37 Fuel and Oil System Components...
Страница 84: ...Engine Maintenance 84...
Страница 96: ...Refrigeration Maintenance 96...
Страница 118: ...Hilliard Clutch Maintenance 118...
Страница 136: ...Cycle Diagrams 136...
Страница 140: ...Wiring and Schematic Diagrams Index 140...
Страница 141: ...141 Truck S Model SR 30 Schematic Diagram Page 1 of 2...
Страница 142: ...142 Truck S Model SR 30 Schematic Diagram Page 2 of 2...
Страница 143: ...143 Truck S Model 30 Units with P T Wiring Diagram Page 1 of 2...
Страница 144: ...144 Truck S Model 30 Units with P T Wiring Diagram Page 2 of 2...
Страница 145: ...145 Truck S Model 50 Schematic Diagram Page 1 of 2...
Страница 146: ...146 Truck S Model 50 Schematic Diagram Page 2 of 2...
Страница 147: ...147 Truck S Model 50 Units with P T Wiring Diagram Page 1 of 2...
Страница 148: ...148 Truck S Model 50 Units with P T Wiring Diagram Page 2 of 2...