Operating Instructions
68
Set Date and Time
1. Press the
F2
or
F3
key to enter the menu list.
Press the
F2
or
F3
key to scroll to [MISC.
FUNCTIONS].
2. Press the
F4
key to access the Misc. Functions
menu. [DATE TIME] appears in the LCD
display.
3. Press the
F4
key to access the Date Time
screen. Date Time screen appears with cursor
in the Time menu line. Display shows time in
“HH.MM.SS” where H = hour, M = minute
and S = second.
4. Press the
F4
key with cursor in [TIME] menu
line to enter a new time. An Enter Arrow
appears in the menu line and the previous time
disappears.
5. Enter new time in [HH.MM.SS] format.
Decimal points must be included in the entry
between the hour, minute and second.
NOTE: To scroll backward in the [TIME] or
[DATE] menu line, press and hold the
F4
key, then press the
F3
key. Press the
F1
key
to return keyboard to “numerical” entry
before typing again.
6. Press the
F4
key. Then press the
E
XIT
key to
enter time in controller memory. Cursor stops
blinking and new time appears in display.
7. Press the
F3
key to move cursor to Date menu
line to enter a new date. Display shows date in
and date in “YY.MM.DD” where Y = year, M
= month and D = day.
8. Press the
F4
key with cursor in “DATE” menu
line. An Enter Arrow appears in the menu line
and the previous date disappears.
9. Enter new date in [YY.MM.DD] where Y =
year, M = month and D = day. Decimal points
must be included in the entry between the
year, month and day.
10. Press the
F4
key. Then press the
E
XIT
key to
enter date in controller memory. Cursor stops
blinking and new date appears in the display.
11. Press the
ESC
key to exit the Date Time
screen.
View or Set Run Time
1. Press the
F2
or
F3
key to enter the menu list.
Press the
F2
or
F3
key to scroll to “MISC.
FUNCTIONS”.
2. Press the
F4
key to access the Misc. Functions
menu. “Date Time” appears in the LCD
display. Press the
F2
or
F3
key to scroll to
“RUN TIME”.
3. Press the
F4
key to access the Run Time
screen. The Run Time screen appears with
cursor in “HEAT” menu line.
4. Press the
F2
or
F3
key to scroll cursor up or
down through cargo data list:
•
[HEAT]
•
[COMPRESSOR]
•
[EVAPORATOR HIGH]
•
[EVAPORATOR LOW]
•
[CONDENSER]
•
[TOTAL]
5. To reset an hourmeter or set hours on a
replacement controller:
a. Press the
F4
key with cursor in the desired
menu line. The Password screen appears.
b. Press the
F2
key,
A
key (password is “A”),
F4
key and then the
E
XIT
key. An Enter
Arrow appears in the hourmeter line.
c. Enter the desired run time setting (up to 5
characters).
d. Press and hold the
F4
key until the cursor
stops flashing. The new run time appears
in the menu line.
6. Repeat step 5 to reset additional hourmeters.
7. Press the
ESC
key to exit the Run Time
screen.
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...