Operating Instructions
60
3. Press the
F4
key to access the Datalogger
menu. [INSPECT TEMP LOG] appears in the
LCD display.
4. Press the
F4
key to enter Temp Log. LCD
display shows the Log Time and the Setpoint,
Supply and Return temperatures of the most
recent log in the first screen.
5. Press the
F3
key to scroll through previous
logs of the sensor temperatures currently in
the display. All temperature logs recorded in
the datalogger memory may be viewed on the
LCD display.
6. Press the
F4
key again to view additional
sensor log and event flag screens. LCD
display shows USDA1, USDA2, USDA3,
Relative Humidity (rH), Ambient, sensor
readings, and flags etc.
7. Press the
F3
key to scroll through previous
logs of the sensor temperatures currently in
the display.
Event Flags for Temperature Log
T = Tripstart Activated
P = Primary Power Off
D = Defrost in Last Interval
O = Temperature Not In-range
h = Humidity Control Active
E = Evaporator High Temperature
H = High Refrigeration Pressure
d = Defrost terminated on time limit
e = Economy mode activated
s = Reefer unit stopped (after PTI)
w = Water-cooled operation (water pressure
switch is closed)
A = Alarm in last interval
R = Condenser Temperature Limited
L = Power Consumption Limited
F = PTI Activity
V = AFAM Door Open
B = Bulb Mode
W = Warning in Last Interval
C = CO
2
Active
NOTE: All event flags that occurred during a
log interval are displayed.
8. Press the
ESC
key to exit the Temp Log.
Inspect Event Log
With the
U
NIT
O
N
/O
FF
switch
O
N
and the LCD
display showing the standard display (setpoint):
1. Press the
F2
or
F3
key to enter the Main
menu.
2. Press the
F2
or
F3
key to scroll through Main
menu until [DATALOGGER] appears in LCD
display.
3. Press the
F4
key to access the Datalogger
menu. [INSPECT TEMP LOG] appears in the
LCD display.
4. Press the
F2
or
F3
key to scroll through
submenu until [INSPECT EVENT LOG]
appears in LCD display.
5. Press the
F4
key to enter PTI log. LCD
display shows the Start Time and PTI test
results of the most recent PTI log.
•
To scroll through additional test results in
the log, press the
F3
key.
PTI Examples
•
PTI stores volt and amps of all power
consuming components
•
PTI stores temperatures logged at both the
start and end of Chilled mode and Frozen
mode capacity tests
6. Press the
ESC
key to exit the Event log.
Calibrate USDA Probe (Optional)
Setting the USDA Type in the Configuration
menu activates spare sensors 1, 2, 3 and 4 for
USDA Cold Treatment Temperature Recording.
USDA sensor temperatures are recorded in the
datalogger memory.
The USDA sensors should be connected to the
controller and located in the load as shown in
USDA directives. When a USDA sensor is
installed, the controller will automatically detect
Содержание 098916
Страница 2: ...MAGNUM TK 51122 4 MM Rev 6 02 06 Copyright 2004 Thermo King Corp Minneapolis MN USA Printed in USA...
Страница 5: ......
Страница 11: ...Table of Contents 10...
Страница 19: ...Service Guide 18...
Страница 28: ...Specifications 27 Figure 2 Physical Specifications AMA313...
Страница 41: ...Unit Description Features Options 40...
Страница 105: ...Operating Instructions 104...
Страница 155: ...Servicing The Unit 154...
Страница 187: ...Index 186...
Страница 189: ...Wiring and Schematic Diagrams Index 188...
Страница 190: ...189 Wiring Schematic...
Страница 191: ...190 Wiring Diagram Page 1 of 2...
Страница 192: ...191 Wiring Diagram Page 2 of 2...