Controller Description
45
Software Version 2.3.6 110301
Release Date
New Features
April 2011
Cold Treatment Feature
Cold Treatment (CT) has been added for all prefixes except OOLU.
Multi Temperature Settings
Multi Temperature settings has been add for all prefixes (including OOLU).
Chilled PTI Chilled
PTI test only has been added as a selection under the COMMANDS menu. Test will end
after MAINTAINING 0C (32F) TEST is completed.
Cold Ambient Battery Issue
Heater remains OFF for the first 10 min of unit operation. Once energized will monitor
voltage, if decreased will de-energized heater for 30 min, repeat.
Warning Message 39 Battery Error added
After battery heater is energized and controller does not see temperature rise, will active
Warning 39 Battery Error before Alarm 123 Datalogger Battery Error.
PTI Pull Times Logged
During PTI tests, FULL and CHILL, the pull down or Approaching times are logged. Need
Logview version 5.9.8 or higher to view.
Warning 38 HIGH VOLTAGE ON LINE
High voltage max limit has been increased from >505 VAC to >515VAC.
Power Limit Mode Based on Condenser Temperature
If condenser temperature is >64 C unit will enter power limit mode.
AFAM Door Closes HLX
Units with prefix HLX. The AFAM door will close when Power OFF key is pressed.
MTS and CT Disabled after PTI
After a PTI is completed or unit OFF for >5 days, MTS and CT will be disabled.
RMM Enables for UACU Units
MP4000 has the RMM built in. RMM features enables for prefixes UACU473411 to
UACU473710 (300 units).
Discharge Pressure now in Data Menu
Discharge pressure can now be viewed in the DATA MENU, if no transducer it will be
calculated using Condenser and Ambient temperatures.
Mode Flags Added
Mode flags for MTS, CT, Ca, and Capacity Limitation added to the Temperature log.
Defrost Termination Temperature and Interval Hours Limited
When USDA is ON, user can adjust defrost termination temperature from +4C to +18C or
Interval time from 3 hours to 12 hours. OOCL request, all users
Trip Start All Temperature Logged
When a Trip Start is activated all temperature sensors and RH is logged. Needed for
Logview function.
AFAM PTI Added
AFAM PTI added to COMMAND menu.
Gas Sensor to be OFF when not Selected
To save the life of the gas sensor if AFAM+ is not selected sensor will be not be power ON/
Backlight ON
Display backlight will be on all the time.
Event Log Available in display
Can now view the Event Log on the display. 100 logs back
Display timer
Main display idle for 5 min, Display goes to scroll every 3 sec Set point to Controlling
Sensor Temperature. Additional 5 min goes to scroll every 3 sec Smiley Face to
Controlling Sensor Temperature
Содержание 098203
Страница 2: ......
Страница 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Страница 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Страница 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Страница 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Страница 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Страница 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Страница 263: ......