Structural Maintenance
110
3. Replace the shaft in the housing. Install a new
seal in the retainer cap. Use the original shims
and replace the O-ring if needed.
4. Install the retainer cap assembly over the
shaft, then install the bolts.
5. Torque the bolts in a criss-cross pattern in
equal steps to 80 in-lb (9.04 N•m).
6. Lock the assembly in a vise and set up a dial
indicator to read end-play. To measure the
end-play, rotate the shaft while pushing in one
direction, and set the dial indicator to ‘0’.
Now rotate the shaft and pull in the opposite
direction while reading the dial indicator.
End-play should be 0.001 to 0.005 in. (0.025
to 0.127 mm). If end-play is incorrect, use
different shims to obtain correct end-play.
7. After the correct end-play is obtained, add
approximately 1.5 oz (44 ml) of oil for the
bearings.
8. Lock the assembly in a vise with the vent
facing up. Pour the oil through the top plug
until it runs out of the side hole. Check the
condition of the O-ring used on the plugs and
replace if necessary. Install the top and side
plugs. Clean up any spillage.
9. Place the assembly on the workbench with the
vent up. Rotate the shaft by hand. The shaft
should be free enough to rotate without having
to hold the housing.
Shims available from the Service Parts
Department
0.020 in. (0.500 mm) Thermo King P/N 99-4231
0.007 in. (0.177 mm) Thermo King P/N 99-2902
0.005 in. (0.127 mm) Thermo King P/N 99-2901
CAUTION: Reinstall the assembly into
the unit, making sure the vent is mounted
facing up.
AEA722
1.
Oil Seal
6.
Shaft
2.
Cap and Shims
7.
Housing
3.
O-ring
8.
Breather Vent
4.
Roller Bearing
9.
Oil Plug Screw (Use Oil P/N 203-278)
5.
Splash Guard Tube
Figure 76: Idler Assembly
Содержание 002008
Страница 4: ...4 ...
Страница 25: ...Unit Description 25 Figure 3 Zone 1 Cool Zone 2 Cool and Zone 3 Cool Zone 3 Zone 2 Zone 1 AGA168 ...
Страница 27: ...Unit Description 27 Figure 4 Zone 1 Cool Zone 2 Cool and Zone 3 Heat Zone 3 Zone 2 Zone 1 AGA169 ...
Страница 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Страница 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Страница 114: ...Mechanical Diagnosis 114 ...
Страница 116: ...Electric Standby Diagnosis 116 ...
Страница 120: ...Remote Evaporator Specifications 120 ...
Страница 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Страница 128: ...Remote Evaporator Electrical Maintenance 128 ...
Страница 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Страница 134: ...Remote Evaporator Structural Maintenance 134 ...
Страница 136: ...Remote Evaporator System Diagnosis 136 ...
Страница 140: ...Index 140 ...
Страница 142: ......
Страница 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Страница 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Страница 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Страница 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Страница 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Страница 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Страница 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Страница 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Страница 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Страница 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Страница 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...
Страница 154: ...154 Model 50 Wiring Diagram Page 4 of 5 ...
Страница 155: ...155 Model 50 Wiring Diagram Page 5 of 5 ...