Getting started

1.1

Getting started

Installation

The accumulator tank should stand on a solid surface and be leveled with assistance from the setscrews underneath the tank (not fitted

on all models). The tank models that come without setscrews can be leveled with assistance of a shim. This must be done before the

tank is connected to the pipes and filled with water. See picture below for adjusting the setscrews. Connections not in use must be

plugged appropriately. During water filling, condensed water may emerge on the outside of the tank. This will result in water under-

neath the tank, on the floor. This will cease when the tank is heated. There must be a floor drain in the same room.

To temporarily remove the insulation, for instance if there is a narrow passage to fit the tank through, see the below instructions (not

applicable to all models). All the screws holding the insulation in place is of Torx 10 type.

1

2

3

2

1

1. Start by removing the screws that holds the locks in

place. At the top and bottom.

2. Flip the locks.
3. Remove the screws all the way down. The side is also fit-

ted with a velcro on the inside.

4. Put the insulation back in the reversed order.

Adjust the setscrews according to the measures below.

1

2

3

1. Foot length is 14mm.
2. Maximum length between floor and tank is 39mm, in-

cluding foot.

3. Maximum screw length is 25mm, excluding foot.

Commissioning

Start by filling the tank, then pressurize it. Continue to fill the radiator system (the enclosed water). The working pressure may not ex-

ceed the test pressure (4,3 or 8,6 bars, gauge). A safety valve with releasing pressure of that of the test pressure must always be installed.

Maintenance

Check the safety valve annually by manually opening and closing the valve handle and making sure that water is released. Check annu-

ally all connections for eventual leakage (also peripheral installations, i.e. a heat pump, etc).

Electric installation

The electrical installation must be performed by an authorised installer and follow applicable norms and regulations.

When selecting electrical equipment, it must be selected with approved materials and enclosure class.

Disassembling the product

When disassembling the product, applicable laws and regulations must be observed. Contact your installer for more information.

Installation Guide

WT-C Accumulator tanks

VIBND502

Thermia AB

4

Содержание WT-C

Страница 1: ...Installation Guide WT C Accumulator tanks www thermia com...

Страница 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...

Страница 3: ...Table of Contents 1 Getting started 4 1 1 Getting started 4 2 Model specifications 5 2 1 WT C 5 2 2 WT C FC Front Connection 8 Installation Guide WT C Accumulator tanks Thermia AB VIBND502 3...

Страница 4: ...side is also fit ted with a velcro on the inside 4 Put the insulation back in the reversed order Adjust the setscrews according to the measures below 1 2 3 1 Foot length is 14mm 2 Maximum length betwe...

Страница 5: ...tres 4x12 6x12 Max pressure hot water heater bar 3 Max pressure coil bar 10 Max immersion heater length mm 670 850 Net weight kg 161 191 Immersion heater max output kW 9 2x9 Standing loss S W 101 127...

Страница 6: ...water coil 2x12m 22mm 6 Preheat coil tap water 2x12m 22mm Technical data Storage volume V 473 litres Test pressure 4 3 bar Working pressure 3 bar Rated temperature 100 C Weight 161 kg Standing loss S...

Страница 7: ...20 x3 5 Immersion heater DN50 6 Preheat coil Tap water 3x12m 22 Technical data Storage volume V 721 litres Test pressure 4 3 bar Working pressure 3 bar Rated temperature 100 C Weight 191 kg Standing l...

Страница 8: ...Working pressure Bar 3 6 3 6 3 6 Test pressure Bar 4 3 8 6 4 3 8 6 4 3 8 6 Max pressure coil Bar 10 Max temperature C 100 Max immersion heater length mm 700 710 840 810 950 910 Weight kg 142 164 187...

Страница 9: ...N20 Technical data Total volume 477 litres Storage volume V 466 litres Total coil volume 11 litres Coil surface per coil 3 m2 Working pressure 3 bar Test pressure 4 3 bar Max pressure coil 10 bar Max...

Страница 10: ...03 litres Storage volume V 492 litres Total coil volume 11 litres Coil surface per coil 3 m2 Working pressure 6 bar Test pressure 8 6 bar Max pressure coil 10 bar Max temperature 100 C Max immersion h...

Страница 11: ...Technical data Total volume 721 litres Storage volume V 704 5 litres Total coil volume 16 5 litres Coil surface per coil 3 m2 Working pressure 3 bar Test pressure 4 3 bar Max pressure coil 10 bar Max...

Страница 12: ...0 Technical data Total volume 676 litres Storage volume V 659 5 litres Total coil volume 16 5 litres Coil surface per coil 3 m2 Working pressure 6 bar Test pressure 8 6 bar Max pressure coil 10 bar Ma...

Страница 13: ...ture sensor DN20 Technical data Total volume 971 litres Storage volume V 949 litres Total coil volume 22 litres Coil surface per coil 3 m2 Working pressure 3 bar Test pressure 4 3 bar Max pressure coi...

Страница 14: ...DN20 Technical data Total volume 907 litres Storage volume V 885 litres Total coil volume 22 litres Coil surface per coil 3 m2 Working pressure 6 bar Test pressure 8 6 bar Max pressure coil 10 bar Max...

Страница 15: ...Installation Guide WT C Accumulator tanks Thermia AB VIBND502 15...

Страница 16: ...ed material Thermia reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes bein...

Отзывы: