N
A heat curve and ROOM temperature set too
low will affect the defrost functionality. Make
sure to not go below 16°C on the indoor tem-
perature.
Change the ROOM value as follows:
1. Press either the + or - button once to open and change the ROOM value.
2. Raise or reduce the ROOM value using the + or - buttons to change the indoor temperature.
3. Wait ten seconds or press the left button once to exit the menu.
5.3
Distribution circuit 1 and 2
In addition to the main circuit for heating and cooling two distribution circuits can be controlled individually.
The same parameters are used for these as in the main circuit (menu HEATING).
5.4
Hot water mode
HOT WATER switched on will enable hot water production. With SUPER-ECO switched on, the heat pump will
produce hot water in the most economic way possible. If you should want a prioritization on the amount of hot
water and a faster hot water production you should change mode to either ECO or COMFORT. By activating
TOP-UP the heat pump can immediately start to heat the water heater using the compressor and electrical
auxiliary heater until the tank is fully heated. The TOP-UP function has to be reactivated each time it is needed.
HOT WATER
HOT WATER
TOP-UP
MODE
ON
COMFORT
SUPER-ECO
MODE
ECO
▪
"COMFORT" is the choice for customers with large demands of hot water availability.
▪
"ECO" can be selected as the best compromise between energy efficiency and hot water availability.
▪
"SUPER-ECO" will give the most energy efficient hot water production and is often sufficient for house-
holds with low to moderate hot water consumption.
User Guide
iTec Eco
Thermia AB
AWIE01UG102
15
Содержание iTec Eco
Страница 1: ...User Guide iTec Eco www thermia com ...
Страница 29: ...User Guide iTec Eco Thermia AB AWIE01UG102 29 ...
Страница 30: ...User Guide iTec Eco AWIE01UG102 Thermia AB 30 ...
Страница 31: ...User Guide iTec Eco Thermia AB AWIE01UG102 31 ...