IMPORTANT! READ INSTALLATION AND PRODUCT GUIDE  P/N 81127 

STEP 2 

OPTIONAL MODES 

SILICONE (INCLUDED) 

ThermaSol Steam Bath Co. 1958 Steam Way, Round Rock, TX  78665 

 

Toll-free: 800.776.0711 Fax: 800-887-6414 

 

Visit us online @ www.thermasol.com 

 

81132R Rev B   10/14  JWJ 

 

Once desired fit is achieved coat back 
of control face with supplied silicone. 
Firmly press to wall surface and wipe 
excess silicone from around control. 
Tape into LEVEL position and allow 
24 hours to completely dry. 

i

 

Once finished tile is completed remove mud ring from 
wall. Ensure that a total minimum depth is 5/8” so control 
face sits flush to wall. Connect cable so it is not lost in 
wall. Test fit for flushness. 

STEP 3 

BEFORE TILE -Using the supplied mud ring 
attach to wall face using a few standard 
screws. Then tile to the edge of mud ring. 

 

MUD RING INSTALLATION 

***FOR RECESSED MODERN CONTROLS ONLY*** 

 P/N  SEMR-XX  (XX- DENOTES FINISH) 

STEP 1 

IMPORTANT NOTE: 

Fully test the control system prior to silicone 

DATA CABLE 