80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
YES
Value
Units
100-240 Volts
13
Amps
47-63
Hz
1000
Watts
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.
Input AC Current Waveform (ITHD = 3.28%, 50% Load)
I
RMS
PF
A
-12V
3.3V
5V*
5VSB
2.15
0.99
4.3%
20%
Light
244
12.1/0.1
3.3/4.8
5/4.7
5/0.6
203
83.28%
5.10
1.00
3.3%
50%
Typical
585
12.1/0.3
3.2/11.8
4.9/11.9
4.9/1.4
503
86.01%
10.36
1.00
2.7%
100%
Full
1190
12.2/0.6
3.1/23.5
4.8/23.7
4.6/2.8
987
83.01%
Tested by Electric Power Research Institute, Knoxville, TN.
7/11/2008
Efficiency
%
Rated Output Power
Load
(%)
Rated Specifications
Input Voltage
Input Current
I
THD
(%)
Input
Watts
Fraction
of Load
DC Terminal Voltage (V)/ DC Load Current (A)
Output
Watts
12V (cumulative of 12V1, 12V2, etc.)
12.2/13
12.1/32.6
12/65.1
Test Date
Input Frequency
932
Type
Ecos ID #
Model Number
Serial Number
Year
EPS12V
NA
2008
Manufacturer
86.01%
84.10%
THERMALTAKE
W0132 Toughpower 1000 A
Input and Output Power
Input Watts
Output Watts
0
200
400
600
800
1000
1200
1400
20%
50%
100%
Loading (% of Rated Output Power)
P
o
w
e
r (W
atts)
Efficiency of the Power Supply
30%
40%
50%
60%
70%
80%
90%
0%
25%
50%
75%
100%
125%
Loading (% of Rated Output Power)
E
fficien
cy (%
)
Efficiency %
These tests were conducted as a part of the 80 PLUS program. 80 PLUS is
a computer buy-down program to promote high-efficiency power supplies
(greater than 80% efficiency in the active mode) in desktop computers and
desktop-derived servers.
Input Current and Voltage Waveforms
-200
-150
-100
-50
0
50
100
150
200
0
0.003
0.006
0.009
0.012
0.015
Time (s)
V
o
lt
age (V
)
-15
-10
-5
0
5
10
15
C
u
rrent (A
)
Voltage
Current