Thermal Edge CS011 Series Скачать руководство пользователя страница 1

 
 
 

 

 

User & Technical Manual 

CS011-D48 Series 

Rev 1.2 

 

 

 

Содержание CS011 Series

Страница 1: ...User Technical Manual CS011 D48 Series Rev 1 2...

Страница 2: ...nt of Confidentiality The Manual and other materials contain proprietary information comprising Thermal Edge Inc s trade secrets Please maintain the confidentiality of all proprietary information duri...

Страница 3: ...4 Moving the Air Conditioner 5 Unit Label 5 Operation 6 Preliminary Testing 6 Mounting the Air Conditioner 7 Unit Specifications 8 Options 10 System Faults 13 Digital Temperature Controller Programmi...

Страница 4: ...ecting the Equipment Thermal Edge air conditioning equipment is designed manufactured and packed to prevent damage from normal handling shock and vibration during shipment It is necessary to inspect y...

Страница 5: ...s without damaging the compressor See Mounting the Air Conditioner for more information If air conditioner is to be shipped or transported at any time pack in original packaging and strap to pallet to...

Страница 6: ...Condensate Removal System that changes the excess humidity liquid into a vapor which is then vented to the atmosphere In the event of excess water vapor when the enclosure door has been left open the...

Страница 7: ...less than a 3 clearance for the supply air to one of the coils without affecting performance Mount the air conditioner high on the enclosure in order to cool the hot air at the top of the enclosure P...

Страница 8: ...ovides electrical and refrigeration specifications for the CS011 D48 Series Air Conditioners CS011 Series Nominal Capacity Rating 1 000 BTUH Standard Maximum Ambient 125 F Unit Weight 30 lbs 120VAC Mo...

Страница 9: ...Hurd Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email support thermal edge com SP ENG 211 D48 02 Rev 1 2 9 P a g e THIS PAGE IS INTENTIONALLY LEFT BL...

Страница 10: ...oint Default Settings 105 F Dry Contact High Temperature Alarm Set Point 2 F Recovery Differential 3min Temperature Alarm Delay At the default settings the Dry Contact initial conditions are normally...

Страница 11: ...the Digital Temperature Controller Programming section for details on all default settings Open Door Kill Switch This option provides you with an adjustable and mountable safety switch for your elect...

Страница 12: ...drogen sulfide chlorine etc Condenser and evaporator coils are available with electrostatically applied epoxy coating to prevent corrosion Three options are available to protect the air conditioner fr...

Страница 13: ...time delay A thermal overload protects the compressor against faults In the event that the snowflake status LED is not flashing on the display and the compressor is not running an internal fault may...

Страница 14: ...ey to display its value 4 Use the UP or DOWN arrow key to change its value 5 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow keys or wait 15 seconds wit...

Страница 15: ...min start up delay No Output 2 HA2 Condenser High Temperature Alarm P2 145 F for 3 minutes Compressor Off 2 LA2 Condenser Low Temperature Alarm P2 50 F for 3 minutes No Output 2 CA Evaporator Coil Al...

Страница 16: ...e high efficiency long life sealed ball bearing fans engineered for optimum performance that require no maintenance Keep fan blades clean for optimal performance Fans are removable and attached by plu...

Страница 17: ...e Qty 2 Thermal Expansion Value TXV 32025 1 Compressor 31659 1 Gasket Installation Kit 71410 CS01 Evaporator Fan 41002 2 1 Condenser Fan 41002 2 1 Note Qty 2 Safety Information Unit is carefully desig...

Страница 18: ...on position ON OFF Toggle Switch then Retry Verify input power meets voltage requirements as shown in the UL label YES If problem is still present contact technical support Unit Overheats Insufficient...

Страница 19: ...sor Use meter 3 Check for faulty evaporator fan 3 Measure Temperature at Evaporator Verify Heat Load Requirements Is unit capacity adequate for internal head load Possible low refrigerant Is compresso...

Страница 20: ...ind controller CA YES NO Check Low Pressure Switch Connections and Verify Pressure switch is closed Use meter 3 P1 or P2 NO YES Check probe connections potential faulty probe LA LA2 HA HA2 YES Refer t...

Страница 21: ...g e Physical Dimensions Water overflow excessive Check drain is it plugged YES NO Clean condensate pan and drain add 1 tbsp bleach to upper pan monthly to kill mold Is Air Conditioner sealed against...

Страница 22: ...Hurd Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email support thermal edge com SP ENG 211 D48 02 Rev 1 2 22 P a g e THIS PAGE IS INTENTIONALLY LEFT B...

Страница 23: ...al edge com SP ENG 211 D48 02 Rev 1 2 23 P a g e Electrical Schematics System Schematic Digital Controller Schematic Note Schematics apply to all voltages optional accessories wiring not provided in t...

Страница 24: ...wn product This Warranty does not cover Labor or reimbursement of labor for evaluation removal installation repair or cost of any warranted part except at the Thermal Edge factory in Dallas Texas Use...

Страница 25: ...d address Shipping method Pack unit in a suitable packing for shipment preferably the original packaging if available If suitable packing is not available arrange for packaging to be shipped to you Ai...

Страница 26: ...om the left connect the wires by inserting them into the lower receptacles located on the front of connector in the following order NOTE If using stranded wires it may be difficult to insert into the...