Manual No. 0-4819
3-5
INSTALLATION
E -1. Set Switches on the Command - Control Module (Type 1 Module)
Compare the command - control module to the illustration. Follow instructions in this section for a module with an
external connection cover.
Remove the power supply right side. Set switches on the CCM (Command-Control Module) per the illustrations.
Switch settings and connection details are provided in the Appendix.
CAUTION
Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up static
charges in your body or surroundings before touching the printed circuit boards.
SW1
SW3
SW4
SW5
SW8
3
4
1
2
3
4
1
2
1
2
1
2
1
2
1
2
SW-1-1: Auto Pilot Restart. 1 = ON = Auto Pilot Function enabled.
1 = OFF = Auto Pilot Function disabled (Factory default setting).
SW-1-2: Pilot Delay 2 = OFF, 3 = OFF, 4 = OFF: 0 Seconds (Factory default setting).
SW-1-3: Pilot Delay 2 = ON, 3 = OFF, 4 = OFF: 0.1 Seconds
SW-1-4: Pilot Delay 2 = OFF, 3 = ON, 4 = OFF: 0.2 Seconds
2 = ON, 3 = ON, 4 = OFF: 0.4 Seconds
2 = OFF, 3 = OFF, 4 = ON: 0.8 Seconds
2 = ON, 3 = OFF, 4 = ON: 1.0 Seconds
2 = OFF, 3 = ON, 4 = ON: 1.5 Seconds
2 = ON, 3 = ON, 4 = ON: 2.0 Seconds
SW-3: Gas Preflow Time 1 = OFF, 2 = OFF: 2 Seconds (Factory default setting).
1 = ON, 2 = OFF: 4 Seconds
1 = OFF, 2 = ON: 6 Seconds
1 = ON, 2 = ON: 8 Seconds
SW-4: Postflow Time 1 = OFF, 2 = OFF: 10 Seconds (Factory default setting).
1 = ON, 2 = OFF: 20 Seconds
1 = OFF, 2 = ON: 5 Seconds
1 = ON, 2 = ON: 0 Seconds
SW-5-1: Tip Saver 1 = OFF = Disabled (Factory default setting).
1 = ON = Enabled
SW-5-2: Off Plate 2 = OFF = Disabled (Factory default setting).
2 = ON = Enabled
SW 8-1: Pilot Time 1 = OFF = Short (85 ms.) (Factory default setting).
1 = ON = Long (3 s.)
SW 8-2: Remote Current 1 = ON
(Remote Analog Current Control)
O
N
O
N
Active only when
SW-1-1 is set to ON.
Art # A-04819
Future Use
SW 8-3, SW 8-4: Reserved for Factory use.
Содержание ULTRA-CUT 100
Страница 4: ...Thispageintentionallyblank ...
Страница 8: ...TABLE OF CONTENTS continued ...
Страница 64: ...Intentionally Blank ...
Страница 79: ...Manual No 0 4819 4 15 OPERATION Remote Arc Starter Spark Gap Adjustment Art A 04857 0 063 0 002 1 6 0 05 mm ...
Страница 80: ...Manual No 0 4819 4 16 OPERATION This page intentionally blank ...
Страница 114: ...This page intentionally blank ...
Страница 120: ...TORCH INFORMATION 7 6 Manual 0 4819 This page is blank intentionally ...
Страница 133: ...Manual 0 4819 A 13 APPENDIX This page intentionally blank ...