Manual 0-2503
55
APPENDIX
APPENDIX III: REMOTE WIRING
A-00831
OUTPUTS
INPUTS
11
12
2
5
6
Quick
Disconnect
1
2
6
TB1
Quick
Disconnect
J20
A-00830
Notes:
1. Welding Arc/ON disabled without closing
TB1-3 to TB1-4. This must be done by direct
interface to TB1-3 & TB1-4 or via remote con-
nection J20 Pin 3 to 4.
2. To disable the pilot arc when coolant conduc-
tivity level is high, connect pin 12 to pin 24
and pin 13 to pin 23.
3. Weld Arc On Detect (for use with Synerweld
2100) is enabled with the following wiring
connections*:
• TB1-6 to J20 pin 11
• TB1-7 to J20 pin 12
(If not using J20, wire directly from input/
output interface signals to TB1.)
* Ultima units manufactured after Nov. 1997
are factory-wired; all other units must be
wired by user.
4. Wiring Connections for the 3A Torch with
Auto Wire Feed are through J20 to Quick
Disconnect.