![Thermaflow TH6-210U M3 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/thermaflow/th6-210u-m3/th6-210u-m3_instructions-for-use-installation-and-servicing_1103112002.webp)
THERMAflow Ltd | THERMAFLOW® ELECTRIC COMBINATION BOILER |
Tel: 0870 850 5207
2
PART1
– INSTRUCTIONS FOR USE
1.1
INTRODUCTION
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning the use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision
Please read these Instructions and follow them carefully for the safe and economical use
of your
combination boiler.
This boiler must have been installed by a competent person in accordance with the
current rules in
force in the countries of destination at the time of installation.
The boiler is automatic in operation once the external controls are set e.g. time clock or
programmable room thermostat.
IMPORTANT NOTICE
1.2
Domestic hot water temperature
Hot water is
NOT
user adjustable and is pre-set to 50ºC at the thermostatic mixing valve fitted
on the hot water outlet at the top left of the boiler. It is TMV3 rated for Anti Scald purposes.
The combination boiler is able to provide room heating as part of an under-floor or central
heating system and domestic hot water direct from the cold water supply, without the need for
secondary storage.
1.3
To turn the boiler off
To turn the boiler off, isolate the boiler from both the electrical supplies i.e. the 24hr supply and
the interrupted supply, both isolating switches should be positioned next to the boiler.
1.4
Maintenance and servicing
To ensure the continued efficient and safe operation of the appliance it is recommended
that it is checked and serviced as necessary at regular intervals. The frequency of
servicing will depend upon the particular installation conditions and usage, but in general
once a year should be enough.
Servicing & maintenance should be carried out by a
competent person
in accordance with the
rules in force in the countries of destination.
To obtain service please call your installer or Thermaflow Ltd, using the telephone number on
the appliance or at the front of this manual.
Please be advised that the Thermaflow log book should be completed by the installation
engineer on completion of commission and servicing.
1.5
Clearances
The boiler requires a clearance in front and at the sides for safety, servicing and maintenance
access, see
diagram 2.2.3
for the requirements.