TABLE 1.8.1 [DATA]
TH6-210U M3
Lift Weight empty
70KG
Total Weight boxed
80KG
Weight Full
278KG
Heating Flow & Return
22mm Compression or push fit
Domestic Cold Water Inlet
22mm Compression
Domestic Hot Water Outlet
22mm Compression
Safety Relief Valve
PRESET 300 KPA (3.0 Bar)
Safety Relief Valve Discharge
15mm Compression
Water Content Primary
200
Water Content Domestic (Secondary)
2 Litres / 0.44 Gallons
Primary Expansion
INTERNAL
22 Litres / 4.9 Gallons. 28 Litres 6.3 Gallons
Secondary Expansion Vessel
0.5 Litres/0.11 Gallons
CH Cold Fill Pressure Min/Max
90 KPA (0.9 Bar) minimum / 120 KPA (1.2 Bar) maximum
D.H.W Working Pressure
20
– 300 KPA (0.2-3.0 Bar)
Max. CH system Content (Excluding unit volume)
100Litres
Electrical Mains Supply
~230-240V, 50Hz
Electrical Rating (Interrupted) & Supply Current
TH6/ 5400-6000w
–25 amp
MCB Rating (amp)
6Kw (26amp) 32 A TYPE B MCB
Electrical Rating (24Hr) Control Circuit
95w, Fused 3amp or 6A Type B MCB