Service Manual for the Thermador Pro Harmony Range, Model PRL364GDH/01
58300000154022_ARA_EN_D
Page 38 of 68
Caution
When installing the 5-Position Oven Function Selector, make sure to
attach the connector correctly onto all of the pins.
Figure 62: Oven Function Selector Screws on Bezel
Figure 63: Multi-Pin Connector on 5-Position Oven Function Selector
6.3.10 Dual Valve Removal and Replacement
There is one dual valve on the 36-inch range.
Prior to Servicing the Dual Valve
■ Turn off the gas supply to the appliance
■ Turn off electrical power to the appliance
1. Follow all safety precautions and steps in
, page
2. Follow all steps in
Accessing Components under the Maintop
3. Disconnect all four blade connectors from the dual valve, and
make a note of which wires are connected to each of the different
terminals (see Figure 64, page 39).
NOTE:
It is always recommended to label and tag all wires and
harnesses prior to disconnecting them, so as to correctly identify
their connections/locations when reassembling.
HINT:
Alternatively, you can photograph the wire connections
prior to disconnecting (for example, with your mobile phone).
4. Use a 1/4
inch wrench to unscrew the gas tube hex nut from each
of the three gas tubes attached to the dual valve. Be careful not to
bend the gas tubes (see Figure 64, page 39).
5. Remove and retain the two T-20 screws on the side of the support
bracket that is secured to the dual valve (see Figure 65, page 39).
You do not have to remove the screws securing the support
bracket to the chassis.
NOTE:
For PRL364GDH/01, the support bracket will either have
two or three screws securing it to the chassis (see Figure 65,
page 39).
6. Remove and replace the dual valve if necessary.