Safety Sticker
WARNING!
Plasma arc is generated immediately
when the torch trigger is depressed.
Plasma arc is generated immediately when the torch trigger is
depressed. The plasma arc will cut quickly through gloves and skin.
Make sure the power is switched off before changing consumables.
Torch consumable installation
Safety instructions
EX-0-904-004
N-21504
1. Screw the electrode. Use the electrode wrench
(EX-2-427-010). Do NOT overtighten electrode.
2. Insert the swirl ring. Must seated properly. CAUTION:
Direction of the swirl ring is important! The tip of the laser
marked arrow indicates the installation direction!
3. Perform free movement test of the electrode inside the swirl
ring (by pushing the electrode).
6. Screw on the hand (contact) shield (tighten by hand).
Do NOT overtighten.
+
=
+
1
2
3
4
6
2.1
3.1
3.2
3.3
4.1
4.2
4.3
5.1
5.2
5.3
6.1
6.2
6.3
5
7
4. Fit the nozzle on to the swirl ring.
5. Screw on the nozzle retaining cap and tighten by hand.
Do NOT overtighten.
Hand Shield
Содержание EX-TRAFIRE 30H
Страница 49: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 49 Notes...
Страница 50: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 50 Notes...
Страница 51: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 51 Notes...
Страница 52: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 52 Notes...
Страница 54: ...EX TRAFIRE 30H Operator Manual Revision T 15 12 54 Revision history...