The Ultra-Aire 90H dehumidifier performs multiple functions in 
a compact enclosure; high-capacity dehumidification, fresh air 
ventilation, and particulate filtration. 

Dehumidification  

The highly efficient UA-90H dehumidifier utilizes refrigeration to cool 
the incoming air stream below its dew point. This cooled and drier 
air is used to pre-cool the incoming air stream resulting in increased 
overall efficiency. After the pre-cooling stage the processed air is 
reheated by passing through the condenser coil. The heat removed 
by the evaporator coil is then returned to the air stream.

Fresh Air Ventilation (optional)  

Fresh air may be ducted to the unit and regulated by a variety of 
controls in order to provide desired ventilation rates. 

Air Filtration  

The UA-90H includes particulate filtration to improve the indoor 
air quality of your living/working space. MERV-11 media filter is 
standard. 

© 2009 Therma-Stor LLC • Manual P/N TS-591

4201 Lien Rd. Madison, WI 53708 

 TOLL-FREE 1-800-533-7533 

 www.thermastor.com 

 [email protected]

INSTALLER’S & OWNER’S MANUAL

HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER

P/N 4029820  •  Serial No.________________________ Install Date:___________ 
Sold by:

Содержание Ultra-Aire 90

Страница 1: ...e condenser coil The heat removed by the evaporator coil is then returned to the air stream Fresh Air Ventilation optional Fresh air may be ducted to the unit and regulated by a variety of controls in...

Страница 2: ...Crawlspace 8 4 4D Installation in an Attic 8 4 4E Installation in a Structure with No Forced Air HVAC System 8 4 4F Ducting for High Efficiency Filtration 9 4 5 Compressor Release and Noise Abatement...

Страница 3: ...den utility room or family room The ductwork of the existing heating system can be used to supply air to the home 2 Registrations The UA 90H conforms to UL STD 474 and CSA Standard C22 2 No 92 3 Speci...

Страница 4: ...rately sense the relative humidity such as near HVAC supply registers near exterior doors on an outside wall near a window or near a water source The installer must supply the wiring between the UA 90...

Страница 5: ...heating system can be used to supply air to the home If the existing supply goes to isolated areas of the home discharge the supply of the UA 90H into the supply of the existing heating system Instal...

Страница 6: ...re only used for 90 flow option 180 Flow B Upward out of the top 90 flow Remove the 10 circular knock out from top panel of dehumidifier using side cutters Attach three white plates using three 8 scre...

Страница 7: ...the structure to the 6 inlet of the UA 90H Advantages of this form of ventilation include 1 Outside air is filtered before entering the building 2 Outside air will be dehumidified before entering if t...

Страница 8: ...ion in an Attic with an Existing Forced Air HVAC System CAUTION ALWAYS install a catch pan with a drain or float interrupt for condensate under the UA 90H in an attic or condensate may damage the livi...

Страница 9: ...that may be installed with the UA 90H The filter box is ducted to the intake of the UA 90H and the intake ducting is then connected to the intake side of the filter box See the optional accessories l...

Страница 10: ...trol Blue Dehumidification fan and compressor control Red 24volt AC power transformer neutral side common with white White 24volt AC power transformer neutral side common with red Yellow transformer h...

Страница 11: ...Humidity Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Se...

Страница 12: ...filter s ability to trap particles ranging in size from 3 0 microns to 10 0 microns Residential filters commonly have MERV ratings of 1 12 The higher the MERV rating the more efficient the filter is a...

Страница 13: ...s List UA 90H Indoor Air Quality System Item Part No Description 1 4029168 Compressor 2 4029169 Compressor Overload 3 4022484 Compressor Relay SPST 24 Vac 30A 4 4029845 Compressor Run Capacitor 45 MFD...

Страница 14: ...h pressure and temperature 10 2 Troubleshooting Neither fan nor compressor running Dehumidification is being called for No fan call 1 Unit unplugged or no power to outlet 2 Humidity control set too hi...

Страница 15: ...HAZARD Electrical power must be present to perform some tests These tests should be performed by a qualified service person 10 5 Electric Ventilation Damper The electric ventilation damper is control...

Страница 16: ...lter door is facing upward Note the locations of the four leveling feet and the hose adaptor Step 2 Partially screw in the leveling feet at the four locations Step 3 Hand tighten the hose adaptor to g...

Страница 17: ...e pump and the short end onto the adaptor Make sure that the hose fully covers the adaptor barbs Step 9 Adjust the height of the leveling feet to move the level bubble into the clear area of the windo...

Страница 18: ...sts related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibili...

Страница 19: ...n any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved 4201 Lien Rd Madison WI 53704 Pho...

Отзывы: