background image

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

Owner’s Manual   —   Phoenix 200 MAX

Installation, Operation & Service Instructions

Read and Save These Instructions

Phoenix 200 MAX

TS-262C

The Phoenix 200 MAX is one of the most effective and versatile drying devices available. The 200 
MAX removes more water and has more grain depression than other refrigerant dehumidifiers, even 
though it only requires 7.4 amps of electricity.
The term LGR (Low Grain Refrigerant) was created to describe the unique drying capabilities of the 
Phoenix 200 dehumidifier. These units were known for delivering substantially drier air, as well as 
for drying areas to much lower humidity levels than conventional dehumidifiers. The Phoenix 200 
MAX, an improved version of the original Phoenix 200, is the culmination of over a decade of LGR 
manufacturing and design expertise.

 The Phoenix 200 MAX LGR,  

High Capacity Dehumidifier 

•   Improved water removal 

  +6 gals/day (33 pints) AHAM (80ºF, 60%) 
  30 gals/day maximum

•   Improved grain depression 

  The driest air from an LGR

•  Multiple air filter options 

 Standard 65% MERV-, 57% MERV-8, or  
95% MERV-4

•   Multiple ducting options 

  2” intake, 0” lay-flat exhaust

•   Less than 7.5 amps 

  Removes the most pints of water per kilowatt

•   Stainless steel cabinet

•   Internal pump with 30 feet of hose

•   Five-year warranty on the sealed refrigeration     
  system.

Phoenix 200 MAX
PN 4024920

Specifications subject to change without notice.

Revised 1/07

PO Box 8680 • Madison, WI 53708

Содержание Phoenix 200 MAX

Страница 1: ...s for drying areas to much lower humidity levels than conventional dehumidifiers The Phoenix 200 MAX an improved version of the original Phoenix 200 is the culmination of over a decade of LGR manufact...

Страница 2: ...e used INDOORS ONLY If used in a wet area plug it into a GROUND FAULT INTERRUPTER DO NOT use the Phoenix 200 MAX as a bench or table It must always be used in the upright position Read the operation a...

Страница 3: ...ft in the condensate pump reservoir for moving or storage Pressing and holding the pump purge switch will cause the condensate pump to run Hold the switch in until the flow from the condensate hose st...

Страница 4: ...ain it completely Walk under out of the hose to open end If the unit will not be exposed to freezing temperatures an alternative to reduce biological growth is to flush the unit with a bio fungicide t...

Страница 5: ...r but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle Sec 2 9 4 7 4 Air filter d...

Страница 6: ...motor the compressor must be replaced 9 Disconnect the wires from the capacitor Set the ohmmeter to the Rx1 scale the capacitor is shorted and must be replaced if continuity exists across its terminal...

Страница 7: ...tween the accumulator and compressor If the low side refrigerant temperature drops due to excessive frost formation on the evaporator coil the thermostat opens The compressor is then cycled off and on...

Страница 8: ...www thermastor com sales thermastor com Toll Free 1 800 533 7533 Figure 3 Electrical schematic of 200 MAX 5 Wiring Diagram...

Страница 9: ...1 Filter Drier 11 4024073 2 Foot 12 4026094 1 Handle Assembly 13 4021597 1 Hour Meter 14 4024918 1 Instruction Label 15 4022219 1 Low Pressure Control 16 4021796 1 Pump Purge Switch 17 4021822 1 Power...

Страница 10: ...10 www thermastor com sales thermastor com Toll Free 1 800 533 7533 This page intentionally left blank...

Страница 11: ...rmal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installat...

Отзывы: