1-16
Themis Computer
RES-12XR3 Installation Manual - Configuration 7
Version 1.1
1.8.2.2 Output Voltage
The RES-12XR3 power supply provides output voltages that are split between
+3.3V, +5V, +5Vsb, +12V, and -12V rails.
1.8.3
Environmental
1.8.3.1 Shock
The RES-12XR3 is designed to survive an elevated shock environment. All struc-
tural components are welded together, enabling the system to survive a maximum
3-axis shock load of 35G at 25-ms duration.
1.8.3.2 Electrostatic Discharge
The RES-12XR3 is designed to tolerate electrostatic pulses up to 15 kilovolts (KV)
with no impact on system operation.
1.8.3.3 Noise
The RES-12XR3 conforms to the 54-db noise specification
Note:
All RES systems are shipped with BIOS fan speed set to the quietest mode.
The default fan speed control mode of the RES-12XR3 Configuration 7 is
Energy
Saving/ES.