1
TR 610 top3
6100130
TR 612 top3
6120130
307253
Time switch
EN
1. Basic safety information
Danger of death through electric shock or fire!
¾
¾
Installation should only be carried out by a
qualified electrician!
WARNING
•
The device is designed for installation on DIN top hat
rails (in accordance with EN 60715)
•
The device corresponds to type 1 STU in accordance with
IEC/EN 60730-2-7
•
Power reserve (10 years) is reduced if memory card is
inserted (using battery power)
2. Proper use
•
The time switch is used for lighting, ventilation and
flushing applications etc.
•
Only for use in closed, dry rooms
!
Do not use on safety devices, e.g. escape route doors, fire
safety equipment etc.
Disposal
¾
Dispose of device in environmentally sound manner
3. Installation and connection
Mounting the time switch
Danger of death through electric shock or fire!
¾
¾
Installation should only be carried out by a
qualified electrician!
WARNING
clic
Test tap
45° cable
Plug-in screwless
terminal NC
contact
Bluetooth
OBELISK top3
(9070130)
DuoFix plug-in
terminal
!
Check the depth of the control cabinet when OBELISK
top3 is connected. The depth must be > 94 mm.
¾
Mount on DIN top hat rails (as defined in EN 60715)
¾
Switched voltage-free
¾
Ensure device cannot be switched on
¾
Check absence of voltage
¾
Earth and bypass
¾
Cover or shield any adjacent live components
Connecting the cable
Wiring diagrams 6100130 / 6120130
C1
1 2 3
L N
N
L
L
C2
C1
1 2 3
4 5 6 L
N
L
L
N
¾
Strip cable to 8 mm (max. 9)
¾
Insert cable in the open DuoFix plug-in terminal at 45°
L
2 cables per terminal position possible
¾
To open the DuoFix plug-in terminal, press screwdriver
downwards
Disconnecting the cable
¾
Use the screwdriver to push the load line connection
opener downwards