1. General Information

These instructions should be read carefully and retained for 
further reference and maintenance.  

Timeguard reserve the right to alter these instructions 

 at any time. Up to date instructions will always be available 
for download at www.timeguard.com 

2. Safety

• Before installation or maintenance, ensure the mains supply
   to the luminaire is switched off and the circuit supply fuses 
   are removed or the circuit breaker turned off.  
• It is recommended that a qualified electrician is consulted or
   used for the installation of this luminaire and install in 
   accordance with the current IEE wiring and Building 
   Regulations.  

• Check that the total load on the circuit including when this
   luminaire is fitted does not exceed the rating of the circuit 
   cable, fuse or circuit breaker.  

• To clean use a clean dry cloth only. Do not use liquid cleaners.

3. Technical Specifications

•  Class Protection:                  Class I  

Note:

•  IP Rating:  

               IP44 

•  Operating Temperature:      

 

0

˚

 to 40

˚

C

•  PIR Switching Capacity:        x2 35W Halogen or
 

 

               x2 15W LED

 

•  Mains Suppply:                    220-240V AC 50Hz

1

Содержание TIMEGUARD UDB2PIR

Страница 1: ...LED Ready PIR Up Down Light Model UDSS2PIR Silver Finish Model UDB2PIR Black Finish I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s ...

Страница 2: ... circuit breaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this luminaire and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean use a clean dry cloth on...

Страница 3: ...cting a location 2 The PIR has a number of detection zones at various horizontal and vertical angles as shown below A moving human body or object needs to cross one of these zones to activate the sensor The optimum height for this is between 1 5m 2m mouting height Careful positioning of the luminaire is required to ensure the best performance from the PIR and the appointed approach path Effective ...

Страница 4: ... by removing the two nuts Avoid positioning the luminaire near any sources of heat in and around the detection area such as extractor fans tumble dryers or boiler exhauhsts etc This would also include other light sources such as secuirty lights Reflective surfaces i e pools of water white painted walls overhanging branches and other types of foliage may cause false activation under heightened weat...

Страница 5: ...ehind the surface Pass through the mains supply cable into the wall plate via the grommet cable grand ensuring there is a tight grip on the cable to maintain the IP rating of the luminaire Mount the wall plate to the wall using the fittings provided Connect the mains supply to the revelant terminals ensuring the correct polarity is observed and that all bare conductors are sleeved see section 5 Co...

Страница 6: ...n the two nuts hand tight to secure the fitting 6 Connection Diagram Connect the 230V AC 50Hz mains supply cable as follows Isolation Switch Brown or Red Blue or Black Note that the earth terminal is attached directly to the fitting This is to ground the metalic exterior of the luminaire ...

Страница 7: ...red and the lamp will turn ON for the minimum set amount of time Once you are happy with the pickup area of the PIR you can set the Lux dial in the clockwise direction to trigger when dusk is approaching This may be best performed in real time in the evening subject to the users preferance You can also adjust the middle dial which will vary the sensitivity range of the pickup area of up to 7m Walk...

Страница 8: ... until the fitting is set back to auto mode To return to auto mode switch the internal wall switch OFF ON again within 2 seconds The unit will return to auto mode and now operate as setup after the walk test procedure 7 1 5 2 0M 7M 3M 5M appro 90 Detection Area 9 Troubleshooting Guide Problem Cause Solution The luminaire does not switch on when in the detection area Bulb faulty or missing Nearby l...

Страница 9: ... of the UK All shipping costs are to be paid in advance before a replacement is sent 8 Problem Cause Solution False activation Luminaire switches on for no apparent reason Heat sources as described in section 4 Reflective surfaces described in section 4 Moving pedestrians cars or animals in the area Check the detection area Nearby electromagnetic disturbance from a neighbouring circuit CCTV interf...

Страница 10: ...ard com or call the helpdesk on 020 8450 0515 Qualified Customer Support Coordinators will be online to assist in resolving your query For a product brouchure please contact Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 02084521112 or email csc timeguard com www timeguard com 67 058 682 Issue 1 T W May 2021 ...

Отзывы: