background image

Presence Detector With

360º Surface Mount PIR

Model: PDSM361AB

(1 Channel)

In

s

ta

ll

a

tio
n

 &

 Op
e

rati
ng
 In
s

tru
ctio

n

s

Optional Absence Detection

Содержание Timeguard PDSM361AB

Страница 1: ...Presence Detector With 360º Surface Mount PIR Model PDSM361AB 1 Channel I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Optional Absence Detection ...

Страница 2: ...reaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit including when this PIR is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean use a clean dry cloth only Do not use liquid c...

Страница 3: ...Construction Polycarbonate Dimensions H x W x D 105mm x 105mm x 48mm PIR Ceiling Projection 48mm If a 2 channel surface PIR is required model number PDSMSB Surface Mount Box along with PDFM362AB 2 Channel Flush Mount PIR can be combined to work as a 2 channel surface mount PIR The flush and surface base plates are interchangable PDSMSB Sold Separately Note Absence mode can only be triggered via us...

Страница 4: ...to ensure the best performance from the PIR and the appointed approach path Effective Approach Path ACROSS Ineffective Approach Path TOWARDS Avoid positioning the PIR near any sources of heat in and around the detection area such as extractor fans tumble dryers or boiler exhausts etc This would also include other light sources such as security lights Reflective surfaces i e pools of water white pa...

Страница 5: ... are removed or the circuit breaker turned off An isolating switch should be installed to enable the power to be switched ON and OFF to the PIR This allows the unit to be easily switched OFF for maintenance purposes Mark the position of the fitting holes using the base of the PIR as a template taking care to avoid ceiling joists and other obstructions within the installtion area Take note of the h...

Страница 6: ...points on the base plate for the installation required Pass the 230V 50Hz mains supply and load cables through the hole and prepare for termination Drill the holes and insert the rawl plugs into position Secure the base plate to the ceiling using the screws provided ...

Страница 7: ...Red to Neutral BlueorBlacktoN Locate the terminal connections and terminate the cables into the terminal block ensuring that the correct polarity is observed and that all bare conductors are sleeved See Section 6 Connection Diagram When wiring is complete tighten the non dropping screws shown in the above illustration to secure the PIR to the base plate and ensure not to over tighten ...

Страница 8: ...tion area when the PIR is triggered and the load will turn ON for the minimum set amount of time Once you are happy with the pickup area of the PIR you can set the Lux dial in the anticlockwise direction to trigger when dusk is approaching This may be best performed in real time in the evening subject to the users preference You can also adjust the time dial which will vary the timeout peroids of ...

Страница 9: ...wards as long as detection in the area has constant movement the PIR will continue to keep the luminaire or attached load swtiched on until the subject has moved out of the detection area and the time delay function takes over For example if set to 10 minutes the PIR will begin to countdown from this value once nothing is in the detection area If a subject is detected the time delay will reset Swi...

Страница 10: ...he IR10AB is an optional remote control that is sold separately If absence detection is required the IR10AB will be needed to change modes over LUX control adjustment Auto mode only Time delay adjustment up to 60 minutes Auto mode only Independent channel control PDFM362AB only Sensitivity control Manual override ON OFF 10 hours Learn mode Set for a specific Lux level Lock Unlock PIR settings Semi...

Страница 11: ...de of the UK All shipping costs are to be paid in advance before a replacement is sent Problem Cause Solution False activation Luminaire switches on for no apparent reason Heat sources as described in section 4 Reflective surfaces described in section 4 Moving pedestrians cars or animals in the area Check the detection area Nearby electromagnetic disturbance from a neighbouring circuit CCTV interf...

Страница 12: ...d com or call the helpdesk on 020 8450 0515 Qualified Customer Support Coordinators will be online to assist in resolving your query For a product brouchure please contact Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 02084521112 or email csc timeguard com www timeguard com 67 058 684 Issue 1 T W October 2021 ...

Отзывы: