RAMSES 812 BLE

8120150

307400

Clock thermostat

EN

1.  Basic safety information

Danger of death through electric shock or fire!

¾

¾

I

nstallation should only be carried out by a 

qualified electrician!

WARNING

 

The clock thermostat conforms with EN 60730-2-9 if 
correctly installed

 

Corresponds to type 1 B in accordance with IEC/EN 
60730-2

 

Operation and programming only via 

RAMSES BLE 

app

 

With external input (no SELV, adjustable)

2.  Proper use

 

Heating control for time-dependent monitoring and 
control of room temperature in single-family houses, 

offices etc. 

 

Use in dry rooms with normal levels of domestic 
cleanliness 

Disposal

¾

†

Dispose of device in environmentally sound manner

3.  Installation

Mounting the clock thermostat

Electrostatic discharge!

 

Caution, sensitive electronic components! 

 

When fitting, observe ESD safety measures (elect

-

rostatic discharge).

 

!

Position the clock thermostat on an internal wall, at 

about eye level. 

 

!

Avoid drafts or heat emission.

 

 

L

For wall mounting

¾

†

Attach the mounting plate above the wall outlet for the 

supply line 

.

¾

†

Engage and wire the circuit board carrier 

.

¾

†

First, hook in the upper part of the clock thermostat on top, 

then engage 

¾

†

Put on the cover 

.

Dismounting the clock thermostat

¾

†

Using a screwdriver, loosen the front panel at the two side 

and bottom openings 

.

¾

†

Then release the catches on the left and right and remove 

the upper part of the housing 

.

¾

†

Loosen the plug-in connectors and press the circuit board 

carrier together at the top and bottom 

.

¾

†

Remove the circuit board carrier through the front.

4.  Connection

Power is supplied via L and N (see technical data); the con-

nection to the boiler is made via a relay contact

.

 

!

Disconnect the boiler from mains supply before connec-

ting the thermostat.

 

!

 In order to eliminate the possibility of EMC interference, 
always lay the mains supply feed separate from the 

external input (if one is being used).

 

!

Faulty connections will damage the device.

Содержание RAMSES 812 BLE

Страница 1: ...ition the clock thermostat on an internal wall at about eye level Avoid drafts or heat emission L LFor wall mounting Attach the mounting plate above the wall outlet for the supply line Engage and wire the circuit board carrier First hook in the upper part of the clock thermostat on top then engage Put on the cover Dismounting the clock thermostat Using a screwdriver loosen the front panel at the t...

Страница 2: ...pairing is successful the LED goes out Delete pairing Press the button for 6 s All connections saved in the RAMSES BLE pairing will be deleted red LED flashes Delete the connection pairing also on the smartphone tablet Settings Bluetooth pairing delete respective device RAMSES BLE The PIN will be reset to 0 3 Reset Press the button for 12 s Hardware reset the red LED goes out 6 Settings and functio...

Страница 3: ...etooth icon on the top left of the app flashes Loading additional devices Press device management A window will open Press Further devices will be searched Program In the program menu programs P1 P3 can be changed a new program or a holiday program can be created or Programs P1 P3 can be set edited or deleted A maximum of 24 switching times can be set per pro gram up to a total of 42 LDuring progra...

Страница 4: ...mperature deviations Switching hysteresis 0 2 K bis 1 K 3 External input The external input can be configured for various external sensors Input is active therefore do not use external voltage The connected contact must be floating and electrically isolated The following options are available with the individual sen sors contacts Floor Temperature limit Floor temperature restriction floor temperatur...

Страница 5: ...rlier and reaches the setpoint temperature at 06 00 a m LThe optimisation value depends on the spatial and heating conditions 5 PIN This function can be used to assign a new PIN The factory setting for the PIN is 0 New PIN can be entered 1 6 digits In case of Delete pairing 2nd pairing the PIN is set to 0 If the PIN is 0 the PIN will not be requested during pairing 7 Technical data Supply voltage ...