background image

LUXOR 

LUXOR 426

426 0 000

GB

Installation and  
operating instructions 

Control Unit

D

GB

F

I

PL NL

309 404 01

Содержание LUXOR

Страница 1: ...LUXOR LUXOR 426 426 0 000 GB Installation and operating instructions Control Unit D GB F I PL NL 309 404 01 ...

Страница 2: ...l automatic 10 Page Group control 10 Page Central functions 11 Page Weather 11 Page Min max values 12 Professional electrician operation Page Settings Date time switching program 13 Switch times astronomical etc language location astronomical offset PIN display key channel allocation channel names group names favouite page system Technical data 23 Service address Hotline 24 2 ...

Страница 3: ...plays all time and sensor system information LUXOR 426 has the functionality of an astronomical time switch manual and automatic mode central functions Only to be used in closed dry rooms house office conservatory etc Disposal Dispose of device and batteries separately in an environmentally sound manner Danger of death through electric shock or fire Installation should only be carried out by a qua...

Страница 4: ...e week display Date display Display battery Symbol for status Panic presence simulation clock manual automatic sen sor system manual automatic p q Select line Select settings ok Store and confirm selection change values Options for 6 pages P S n ...

Страница 5: ...sday 04 22 10 11 26 S P w ok Manual automatic Manual Automatic n ok Group control Group Z G1 Group 1 G2 Group 2 G3 Group 3 hi ok Central functions On Activation Activation Off P S ok Weather Temperature 10 C Wind speed 10 min sec Wind Yes Sun 1 No Sun 2 Yes Twilight No Rain No i ok Min max values Since 01 01 10 12 36 00 Min Max Temp 12 36 C Wind 0 5 min sec Rain No Reset ok Settings Back Time date...

Страница 6: ...ectrician Disconnect power source Cover or shield any adjacent live components Ensure device cannot be switched on Check power supply is disconnected Earth and bypass Only use updated new modules in the LUXOR system with LUXOR 426 Do not use LUXOR 426 and LUXOR 414 simultaneously in the LUXOR system WARNING ...

Страница 7: ...m must be firmly clicked into place Ensure installation height of 1 5 m Remove protective film Dismantling Press down on the top of the device with a screwdriver to release the device from the wall Reset Press keys and simultaneously Montage Demontage GB ...

Страница 8: ...ertified electricians Disconnect device from the power supply Insert a screwdriver on the top side and press downward in order to open the device Remove old battery Lithium cell Type CR 2032 from the battery compartment and replace with a new one Ensure correct polarity U COM L N C1 C2 C3 I4 I4 N L L C4 N L I2 I3 I1 LUXOR 400 LUXOR 405 P S C4 G1 COM M L C1 C2 C2 C3 C3 N L N L I3 I4 M M I2 LUXOR 40...

Страница 9: ...by a professional electrician Please refer to the Product Handbook for detailed functional descriptions at www theben de Press key Page time Display of the time as well as the statuses panic presence simulation clock manual automatic sensor manual automatic depending on the modules connected 9 GB User operation ok Thursday 04 22 10 11 26 S P w n ...

Страница 10: ...ange and confirm with ok Page Group control Group control display only if connected to LUXOR 408 409 Press button several times Use p q to select group The symbol appears if the curtain is not moved If necessary select or in order to rise or lower the blinds 10 ok Manual automatic Manual Automatic n ok Group control Group Z G1 Group 1 G2 Group 2 G3 Group 3 hi ...

Страница 11: ...nction Change with or Confirm with ok Page Weather Display weather data Outside temperature wind sun position twilight threshold rain frost etc only if connected for LUXOR 411_412 Press button several times Use p q to select weather data 11 GB ok Central functions On Activation Activation Off P S ok Weather Temperature 10 C Wind speed 10 min sec Wind Yes Sun 1 No Sun 2 Yes Twilight No Rain No ...

Страница 12: ...ues temperature wind speed and rain only if connected to LUXOR 411_412 Press button several times Use p q if necessary to select reset Confirm with ok ok Min max values Since 01 01 10 12 36 00 Min Max Temp 12 36 C Wind 0 5 min sec Rain No Reset ...

Страница 13: ...nel names group names favourite page manual automatic system Press button Use p q to select the desired lines and confirm with ok Use or to select line and confirm with ok Use or to change value and confirm with ok ok ok ok ok ok Settings Back Time date Switching program Language Location Astronomical offset PIN 13 GB Professional electrician operation ...

Страница 14: ...alue and confirm with ok ok Time date Date Time 15 56 16 SUMMER WINTER EU Back Settings Switching program Select switching program with p q and confirm with ok Channel selection appears Select channel e g 1 with p q and confirm with ok ok Thu 04 22 10 i Channel selection Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 ...

Страница 15: ...select new switch time and confirm with ok 2 x Use or to enter hour and minute e g 10 00 am and confirm each with ok If you would like to enter a new astronomical time blocking time etc follow the steps described ok ok Channel 1 Day of the week Friday Details Copy Delete Back Details channel 1 Wed Action 0 6 12 18 24 0 6 12 18 24 15 Details Back ok Details channel 1 Wed Action NewSwitchtime switch...

Страница 16: ...ne and confirm with ok Use or to select week day and confirm with ok Settings Set switching program Delete Use p q to select delete and confirm with ok Use or to select line and confirm with ok Use or to select week day and confirm with ok ok ok Copy Copy to Thu Back Delete Delete from Thu Back Thu Thu ...

Страница 17: ... confirm with ok Settings Set location Use p q to select location and confirm with ok Use p q to select e g Country and confirm with ok Use or to select desired country and confirm with ok ok ok Language Deutsch English Français Italiano Español Nederlands Svenska Back Location Location City Berlin Geogr latitude 009 Geogr longitude 48 Time zone 1 0 Back Deutsch Germany ...

Страница 18: ...ornings and confirm with ok Use or to change e g values and confirm with ok Settings Enter PIN Use p q to select PIN Use p q to select PIN number and confirm with ok Use or to enter number and confirm with ok ok ok Astronomical offset Channel Channel 1 000 min Evening 025 min Back PIN PIN 1234 Back Mornings PIN ...

Страница 19: ... change e g values and confirm with ok Settings Set channel allocation Use p q to select channel allocation and confirm with ok Use p q e g to select manual automatic and confirm with ok ok ok Screen keys Button sound On Button light On Brightness 40 Basic brightness 10 Back Channel allocation Manual automatic Clock Back Brightness Manual automatic ...

Страница 20: ...irm each character letter with ok Use p back and select with or to save Confirm with ok Settings Set group names LUXOT 408_409 groups are renamed here Use p q to select group names and confirm with ok Use p q to select groups 1 3 or Z and confirm with ok ok ok Channel names Old name Channel 1 New name Back Group names Old name Group Z New name Back New name New name ...

Страница 21: ...firm with ok ok Group names Old name Group Z New name Child Save Back Settings Set favourite pages Use p q to select favourite pages and confirm with ok Place the g cursor in the desired page and confirm with ok ok Favourite page Time Group control Central functions Weather Min max values Back g Child ...

Страница 22: ...22 Settings System Professional electrician operation only SW Software version S N Serial number ok System S N 4294967295 SW 00 01 Factory setting Delete switching program Back ...

Страница 23: ... Y Power reserve 1 5 years Permissible ambient temperature 5 C 45 C Protection class II in accordance with EN 60730 1 for designated installation Protection rating IP 20 in accordance with EN 60529 Mode of operation RS Type 1 State of cleanliness 2 Connection terminals max Ø 1 5 mm2 Rated impulse withstand voltage in accordance with 60730 1 Tab 20 1 Installation category III 4 KV Observe deviating...

Страница 24: ...ddress Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Telephone 49 0 74 74 6 92 0 Fax 49 0 74 74 6 92 150 Hotline Telephone 49 0 74 74 6 92 369 Fax 49 0 74 74 6 92 207 hotline theben de Addresses telephone numbers etc www theben de ...