1. Proper use
The weather sensors constitute a combi-device that records
temperature, brightness and wind speed. A rain sensor is also
installed on the top of the device. The device is designed for use
on buildings.
These variables are sent to the LUXOR sensor module 411 via the
COM interface and further processed there.
Wall installation
Secure wall bracket to the wall using screws and washers
provided (see chapter 5).
The washers are important for achieving the IP 44
protection rating.
Feed the cables through the rubber seals, strip cores to 8 mm
and insert in the terminals (provide flexible cores with
crimp terminals).
Loosen screws
.
Push weather sensors down into the wall bracket.
Tighten screw
.
Position weather sensors horizontally and tighten screws
.
4. Installation
Do not install the wind sensor in a sheltered position.
Avoid shadows (e.g. from masts etc.) and reflected
light.
Pay attention to mounting position
– Rain sensor facing upwards
– Rotor facing downwards
Rain sensor
Rotor
Screws:
3. Description
1
2
3
5
4
2. Safety information
Installation should be carried out only by a qualified
electrician!
Rain sensor becomes hot during use!
Do not touch the rain sensor.
• Rain is detected only when the rain sensor is sufficiently
wet. There can be a delay between the first raindrops
in a shower to the point where rain is detected.
• When the rain stops, and despite heating, it can take several
minutes before the sensor is dry again and the
device is able to detect that correctly.
• The wind sensor can freeze at temperatures below freezing
and in wind.
•
Caution
: When it is windy, awnings/blinds
take time to retract.
Enter the wind thresholds according to the value
specified by the awning/blind manufacturer.
1 Rain sensor with heating
2 Light sensors
3 Rotor
4 Temperature sensor
5 Wall bracket with connection for power supply and
communication (with LUXOR 411)
Wall bracket with