Motion detector

EN

1.  Basic safety information

Danger of death through electric shock or fire!

¾

¾

Installation should only be carried out by a 

qualified electrician!

WARNING

 

The device conforms with EN 60669-2-1 if installed 
correctly

2.  Proper use

 

Motion detector for automatic lighting control dependent 
on presence and brightness (LUXA 103-100 AP); LUXA 
103-101 AP: suitable for automatic lighting and HVAC 
control (HVAC switches on regardless of brightness)

 

Suitable for ceiling installation indoors with back boxes

 

Suitable for toilets, small rooms, workplaces, offices, etc.

Disposal

¾

†

Dispose of the device in an environmentally sound manner 
(electronic waste)

3.  Device description

3 potentiometers for setting 

time delay (TIME), bright-

ness value (LUX) and detec-

tion area (METRES) (under 

the cover);

additional setting of HVAC 

time (TIME 2) in the case of 

LUXA 103-101 AP

red LED

4.  Installation and connection

!

  

Secure device with an upstream type C circuit breaker (EN 

60898-1) with a maximum of 10 A (channel 1)

!

  

Secure device with an upstream type C circuit breaker (EN 

60898-1) with a maximum of 6 A (HVAC channel 2)

Installing the motion detector

 

L

Installation height: 2 – 3 m

 

L

Motion detector requires clear line of sight to people 

¾

†

Disconnect power source

0FF

230V

¾

†

Carefully lift the outer cover with a screwdriver and 

unscrew the upper housing part

2

¾

†

Observe the break-outs for flush-mounting socket

B

5 6

60

70

80

84

A

 8 0

84

70

6 0

5 6

 

¾

Strip cable to 6 – 8 mm

6

30 - 35mm

- 8 mm

5

6  

 

6

0  

 

70

  

80

  

8

4

D1  D2

5

6  

 

6

0  

 

70

  

8

0  

8

4

¾

†

Make marks for the holes and drill the holes

60   

56   

60  

 

¾

†

Fix the base to the ceiling, connect the individual wires to 

the appropriate terminal and tighten the screws

¾

†

Screw on the housing

60  

 

56   

60 

  

¾

†

Make settings at the potentiometers

¾

†

Put on the cover and close catch mechanism

¾

†

Connect motion detector to power supply

Содержание LUXA 103-100 AP WH

Страница 1: ... cover additional setting of HVAC time TIME 2 in the case of LUXA 103 101 AP red LED 4 Installation and connection Secure device with an upstream type C circuit breaker EN 60898 1 with a maximum of 10 A channel 1 Secure device with an upstream type C circuit breaker EN 60898 1 with a maximum of 6 A HVAC channel 2 Installing the motion detector L LInstallation height 2 3 m L LMotion detector requir...

Страница 2: ...lamps etc Do not direct the motion detector at objects that move in the wind such as curtains large plants etc Pay attention to the direction of motion during the test run 3 5 m 4 m 7 m 2 m L Lrecommended installation height 2 5 m 5 Walking test The walking test is used to test the detection area Set the time delay potentiometer TIME 1 to Test The motion detector only reacts to movements brightnes...

Страница 3: ...button once The light is on for the time set on the potentiometer then the detector goes into automatic mode Limiting the detection area Use the supplied cover clips to adjust the motion detector to the desired detection area Remove the required section of the cover clip by using pliers or similar Then place it on the lens A B 7 Technical data Operating voltage 230 V AC 10 15 Frequency 50 Hz 60 Hz...

Страница 4: ...4 8 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Tel 49 7474 692 0 Fax 49 7474 692 150 Hotline Tel 49 7474 692 369 hotline theben de Addresses telephone numbers etc www theben de ...

Отзывы: