Chapter 1: Appliance Hardware Functions
Item
Name
Description
C
HSM card USB port
When authenticating with a PED, the PED must be connected directly to the HSM
card. The other USB ports on the appliance will not work for PED connection.
D
LAN ports
The appliance has a total of four (4) 1Gbit LAN ports that can be bonded in active-
backup mode. They are labeled on the illustration above as follows:
>
Bond0: eth0 and eth1
>
Bond1: eth2 and eth3
E
USB 3.0 ports
The appliance has a total of four (4) USB 3.0 ports (two on the front panel and two
on the back), for connecting to such devices as card readers and backup HSMs.
F
RJ45 serial port
Connect a terminal to this port using the included RJ45 to USB cable (see
"SafeNet Luna Network HSM Required Items" on page 1
). See also
SafeNet Luna Network HSM Hardware" on page 1
G
Decommission button
This button should only be pressed as part of decommissioning and zeroizing the
appliance. See also
"Declassify or Decommission the HSM Appliance" on page 1
H
Power supplies
Connect the appliance to power. For proper redundancy and best reliability, the
power cables should connect to two completely independent power sources. See
also
"Power Supply and Fan Maintenance" on page 21
Front-panel LCD Display
The LCD on front panel of the SafeNet Luna Network HSM provides basic configuration and status information
for the appliance. The LCD is split horizontally into three sections as follows:
Figure 1: The LCD display
SafeNet Luna Network HSM 7.3 Appliance Administration Guide
007-013576-005 Rev. A 13 December 2019 Copyright 2001-2019 Thales
12