![TGW IntelliROL 1145930 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/tgw/intellirol-1145930/intellirol-1145930_application-control-manuallines_1099148014.webp)
P/N: 1176718
REV: 02/17/2021
Page
14
of
32
5.4: T
ERMINAL
S
TRIP
C
ONNECTIONS
All output circuit connections are made at a terminal strip. Each IntelliROL power supply has
separate terminals for two Class 1 circuits to supply power to the motorized rollers. For the
Combination power supplies, there are terminals for one Class 2 circuit to supply power to
nearby CRUZcontrol. A power harness is included with each IntelliROL power supply. This can
be used to connect the Class 1 circuits of the power supply to the power harness installed on
the IntelliROL conveyor.
IntelliROL Power Supply Terminal Strip
Splice Kit
A power splice kit is included with each IntelliROL power supply. The splice kit is used to
connect the Class 1 circuits of the power supply to the power harness installed on the IntelliROL
conveyor. These are used only in rare cases when a power supply is not installed at the bed
joint. Reference the manual drawing inside the kit for installation instructions.
Common Carrier Power Cable
A common only power cable is included with each IntelliROL power supply. This is used to keep
a common connection between separate power supplies.