TGS WP-EWG-040U Скачать руководство пользователя страница 1

EMERGENCY INVERTER

WP-EWG-040U

 | for LED High Bay Lights

BC

Self

Diagnostic

General Description

The Emergency Inverter

 

for LED High 

Bay Lights, 

listed for field and factory 

installation, provides constant power 
output to the load during emergency 
mode operation. They maintain 
illumination in the emergency mode for 
a minimum of 90 minutes. It is an ideal 
emergency solution for 

Round/Circular

 

LED 

h

igh

 

bay 

fixtures

.

Features and Benefits

• LiFePO4 safety batteries
• Link to the input of LED drivers
• High PF even during charging
• Safety rope prevent from dropping while

 

installation

• Remote test

 from a

 handh

e

ld controller

• Self-diagnostic every month and year
• RoHS compliant
• 5 years warranty

:9601 Variel Ave. Chatsworth, CA 91311

:info@trulygreensolu�ons.com

:818-206-4404

:www.trulygreensolu�ons.com

1

• Constant power output
• Universal input range
• Integrated junction box design
• Field and factory installation
• IP65 for dry, damp and wet location
• 40W & 90mins durable emergency

operating time

• Surge L-N:3KV; L&N-PE:3KV
• Protection: Over-Voltage ,Short-Circuit,

Over-Load, Open-Circuit

Содержание WP-EWG-040U

Страница 1: ...fits LiFePO4 safety batteries Link to the input of LED drivers High PF even during charging Safety rope prevent from dropping while installation Remote test from a handheld controller Self diagnostic every month and year RoHS compliant 5 years warranty 9601 Variel Ave Chatsworth CA 91311 info trulygreensolu ons com 818 206 4404 www trulygreensolu ons com 1 Constant power output Universal input ran...

Страница 2: ...Vin 120 277Vac 60Hz charging Max Load W 300 Min dim power have to lower than 36W Output Characteristics Parameter Min Typical Max Remarks No Load Output Voltage Vac 250 Emergency Output Power W 36 40 Constant power output Instantaneous Output Power W 100 Emergency cold start peak output last time 10 seconds Power up Time S 0 5 120Vac charging Response Time S 5 Switch from mains supply cuts to Emer...

Страница 3: ...250 Short Circuit Protection mA Power Off Open Circuit Protection mA Abnormal Indicator Light Over Load Protection W 45 Power Off Over Temperature Protection x x x x 9601 Variel Ave Chatsworth CA 91311 info trulygreensolu ons com 818 206 4404 www trulygreensolu ons com 3 Parameter Min Typical Max Remarks Work Temperature 10 50 Discharge time 90mins Work Humidity RH 10 90 Storage Temperature 20 65 ...

Страница 4: ...1 22 Excluding the ring and hook Remarks If not specified all the above parameters are measured in the full load state of the product at Ta 25 Safety Regulation Certificate Approval Marks Standard Valid Remarks UL UL924 North America cUL CAN CSA C22 2 NO 141 Canada BC BC CEC Title 20 California 9601 Variel Ave Chatsworth CA 91311 info trulygreensolu ons com 818 206 4404 www trulygreensolu ons com ...

Страница 5: ...n Remarks 1 The power supply is considered as a component to be used in combination with the terminal equipment Because the Emergency Inverter is affected by the whole device the terminal equipment manufacturer shall confirm Emergency Inverter with the whole device 2 During the voltage test please short circuit the L N the positive and negative of output line and the positive and negative of dimmi...

Страница 6: ...5 18AWG Purple 152mm DIM Output DIM Output DIM Input UL1015 18AWG Grey 152mm DIM Output UL1015 18AWG Red 152mm DIM Output UL1015 18AWG Yellow 152mm Name Code Spec Length L 4 92 Inch Width W 4 92 Inch Height H 11 22 Inch Fixed Hole D1 M12 Fixed Hole D2 G PF 1 2 Fixed Hole D3 1 26 Inch Fixed Hole D4 0 87 Inch Fixed Hole D5 G PF 1 4 Fixed Hole D6 6 32 1 4 Fixed Hole D7 1 26 Inch Fixed Hole D8 NPT 1 2...

Страница 7: ...the button twice in two seconds then press the button longer than 2 sec and less than 5 sec then press the button twice in succession the indicator light will be on and off for 5 times 1 sec interval means disable the Self Diagnostic Test System successfully If you want to enable the Self Diagnostic Test System repeat the operation the indicator light will be on and off for 3 times 1 sec interval ...

Страница 8: ...Wiring Diagram 9601 Variel Ave Chatsworth CA 91311 info trulygreensolu ons com 818 206 4404 www trulygreensolu ons com ...

Страница 9: ... 9601 Variel Ave Chatsworth CA 91311 info trulygreensolu ons com 818 206 4404 www trulygreensolu ons com Wiring Diagram ...

Страница 10: ...on box cover Safety rope LED Driver dimming wire LED Driver input wire Thread mounted hole Hanging hook bolt LED Driver of UFO highbay light Attentions Please use waterproof connectors in position and for application in damp location 9601 Variel Ave Chatsworth CA 91311 info trulygreensolu ons com 818 206 4404 www trulygreensolu ons com 8 ...

Страница 11: ...nnectors in position and for application in wet location 3 It is recommended to seal the dimming connector with an insulating sleeve when the dimming function is not necessary To avoid the signal interfering with the dimming line and cause damage to the power supply 4 Safety rope is an optional component If safety rope is not chosen then it is not needed for installation 5 Verify that the dimming ...

Страница 12: ...e Lag Axial fuse Glass Body or Ceramic Body Φ5 20mm 10A 300V Purpose To ensure the safety of products the blown fuse must be connected to the fixture live wire normal lighting switch control wire black into white wire If short circuit occurs on luminaires or accidentally short circuiting during wiring that may damage the fuse Only operators with relevant permits can open the fuse holder and replac...

Страница 13: ...on gives however it will provide a good reference for the lighting design c Using the results of this calculation and industry standard lighting design tools the expected illuminance in the curve can be calculated Lumens In Emergency Mode Lumens per Watt of Fixture Output Power of Chosen Product ____________________ Lumens __________________ lm W 40 W 9601 Variel Ave Chatsworth CA 91311 info truly...

Страница 14: ...n the output and the LED light source If the product packaging is damaged please confirm whether the product appearance is complete and cracks on the external structure of the product is not acceptable This specification sheet will be subject to change without notice Shipment Storage RoHS ATTENTIONS It is suitable for transportation by car boat and airplane During transportation it should be shelt...

Страница 15: ...attery is a rechargeable LiFePO4 type and must be recycled or disposed of properly Do not use this emergency driver with accessory equipment other than recommended by the manufacturer failure to follow this may cause an unsafe condition Servicing should only be performed by qualified service personnel Do not use this emergency driver for other than intended use Not suitable for high risk task area...

Отзывы: