![TGM CTV14CN018A Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/tgm/ctv14cn018a/ctv14cn018a_technical-manual_1099122031.webp)
14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL
5.Test Operation
(1) The test operation must be carried out after the entire installation has been completed.
(2) Please confirm the following points before the test operation.
●
The indoor unit and outdoor unit are installed properly.
●
Tubing and wiring are correctly completed.
●
The refrigerant pipe system is leakage-checked.
●
The drainage is unimpeded.
●
The ground wiring is connected correctly.
●
The length of the tubing and the added stow capacity of the refrigerant have been recorded.
●
The power voltage fits the rated voltage of the air conditioner.
●
There is no obstacle at the outlet and inlet of the outdoor and indoor units.
●
The gas-side and liquid-side stop values are both opened.
●
The air conditioner is pre-heated by turning on the power.
(3) According to the user's requirement, install the remote controller when the remote controller's
signal can reach the indoor unit smoothly.
(4) Test operation
Set the air conditioner under the mode of "COOLING" with the remote controller, and check the following
points.
Indoor unit
●
Whether the switch on the remote controller works well.
●
Whether the buttons on the remote controller works well.Whether the air flow louver moves normally.
●
Whether the room temperature is adjusted well.
●
Whether the indicator lights normally.
●
Whether the temporary buttons works well.
●
Whether the drainage is normal.
●
Whether there is vibration or abnormal noise during operation.
Outdoor unit
●
Whether there is vibration or abnormal noise during operation.
● Whether the generated wind, noise, or condensed of by the air conditioner have influenced your
neighborhood.
●
Whether any of the refrigerant is leaked.
31
Содержание CTV14CN018A
Страница 1: ...Technical Manual R410A 60Hz 14 SEER Top Discharge Heat Pump Outdoor 1 ...
Страница 9: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 2 Dimension 9 ...
Страница 11: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 4 Wiring Diagrams 18K 24K 30K 36K 42K 48K 11 ...
Страница 12: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 60K 12 ...
Страница 17: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 1 Dimension 17 ...
Страница 18: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 2 Service Space 18 ...
Страница 19: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 3 Wiring Diagrams SEER 14 Cooling only 19 ...
Страница 37: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 3 5 T5 discharge temperature sensor fault 3 6 Low pressure alarm 37 ...
Страница 38: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 3 7 High pressure alarm 3 8 T3 High temperature protection 38 ...
Страница 39: ...14SEER AIR HANDLER SYSTEM TECHNICAL MANUAL 3 9 High exhaust temperature protection 39 ...