25
Figure 7.2 - TFortis-1 Attachment Set.
IMPORTANT!
The Attachment Set is not included in the supply scope.
7.3 Optical connections
The switch has an optical distribution frame. For ease of operation the optical
distribution frame can be removed from the cabinet. The optical cable is pulled
into PG13.5 cable glands. The optical cable is attached to the metal base of the
distribution frame with nylon ties or metal cable ties. To fix the optical cable
strength member, metal supports with screws are used. Optical fibers are laid in
a splice cassette for 32 shrinkable plastic sleeves. Welded pigtails are
connected to SC adapters located on the adapter plane. Then the adapters are
connected to SFP modules with the use of optical patch cords. It is allowed to
connect the pigtails directly to SFP without any unnecessary connections.
IMPORTANT!
Nylon ties, shrinkable plastic sleeves, pigtails and adapters are not included in
the scope of supply.