background image

 

 

 

16 

restore, the switch decides that the camera is hanging and restarts it. The user 
may specify the limit values (see the Configuration Manual).  

3.8.2 Cable tester 

The  switch  can  function  as  a  virtual  cable  tester  (VCT),  which  allows  to 
determine  the  breakage  of  the  twisted  pair,  short-circuiting  of  the  twisted  pair 
wires,  cable  disconnection  from  the  camera,  distance  from  the  switch  to  the 
fault.  The  cable  tester  is  used  to  test  pairs  that  transmit  data  (

1,  2

  and 

3,  6

). 

Note that the accuracy of the cable tester is 

± 2 meters

.  

By  default,  VCT  operates  on  an  average  algorithm  and  does  not  take  into 
account the specific features of a particular cable, which can affect the accuracy 
of  the  measurement.  To  improve  the  accuracy  of  the  cable  tester,  it  is 
recommended  to  calibrate  it.  Note  that  calibration  is  not  recommended  for 
cables 

shorter than 10 meters

.  

3.8.3 Remote camera polling 

Using  the  switch,  it  is  possible  to  ping  any  device  on  the  network  through  the 
web interface, which is convenient when solving network problems. 

 

 

4 Technical specifications 

Gigabit Ethernet ports 

  1000Base-X with SFP connector; 

  Number of ports 

– 2; 

Fast Ethernet ports 

  10/100Base-Tx with RJ-45 connector; 

  number of ports 

– 4; 

  Auto-MDIX support for 10/100Base-Tx port; 

  IEEE 802.3x flow control support; 

  PoE/PoE+  (IEEE802.3af/at)  support  by  option  A  and  B  simultaneously 

– 

up to 60W; 

  total power should not exceed 160 W; 

  transmission distance 

– up to 100 m. 

Power supply 

  voltage 

– 230 VAC (187 to 253 V); 

Содержание PSW-2G+Hot

Страница 1: ...Multifunction Gigabit Managed Switch with PoE support IEEE802 3at up to 60 W per port for connecting four IP video cameras designed to be used in hot climate PSW 2G Hot Operating Manual Version 1 ...

Страница 2: ...y unit under voltage SFP port operates only at 1000 Mbps Fast Ethernet SFP modules will not operate To ensure proper operation of lightning protection provide proper grounding according to the Electrical Code use a shielded twisted pair with shielded RJ45 connectors use minimum length of the twisted pair and power supply cables ...

Страница 3: ...onal functions 15 3 8 1 Restarting cameras in case of hanging 15 3 8 2 Cable tester 16 3 8 3 Remote camera polling 16 4 Technical specifications 16 5 Operating conditions 17 6 Preliminary setting 17 6 1 Resetting the switch to factory settings 17 6 2 IP address setting 17 6 3 User name and password setting 18 6 4 Activation of redundancy protocols 18 7 Installation of the switch 19 7 1 Installatio...

Страница 4: ...4 1 Purpose PSW 2G Hot device is a multifunction gigabit outdoor managed switch designed for the construction of IP video surveillance networks PSW 2G Hot connection scheme ...

Страница 5: ...e gland The key element of the switch is a high performance chip from Marvell which is able to process large amounts of traffic coming from the IP video cameras The switch can supply any video camera compliant with IEEE802 3af or IEEE802 3at standards up to 60W A built in power supply unit ensures direct connection to 230VAC power supply eliminating the need for an additional power supply unit A b...

Страница 6: ...stem The switch enclosure has a tamper sensor Opening of the cabinet door will generate an alarm message to be sent to the server via SNMP or Syslog protocols The optical distribution frame allows for optical cable splicing inside the switch and connecting it to SFP modules The automatic circuit breaker allows to de energize the switch during configuring and debugging Cameras restart automatically...

Страница 7: ...7 3 Description 3 1 Enclosure External view View with the shield removed Figure 3 1 1 PSW 2G Hot switch Figure 3 1 2 PSW 2G Hot interior ...

Страница 8: ...witch The shield is attached to the enclosure at several points to eliminate heat passage from the external casing into the switch All heat generating components of the switch are connected to the enclosure This allows to dissipate heat from electronic components out of the switch A combination of the above technical solutions allows the switch to operate in hot climate Figure 3 1 3 Switch operati...

Страница 9: ...tails and adapters Figure 3 2 1 Optical distribution frame 3 3 Power supply unit The power supply unit is located under the switch board Access to the power supply unit is limited The power supply unit has an aluminum radiator that is pressed against the back panel of the switch to remove the heat to the switch enclosure ...

Страница 10: ...10 Figure 3 3 Power supply unit 3 4 Switch board The switch board is mounted on an aluminum plate that removes the heat from hot electronic components to the switch enclosure Figure 3 4 1 Switch board ...

Страница 11: ...ory settings press the DEFAULT button and hold it down for about 15 seconds The DEFAULT indicator should set ON at this point 3 4 3 CPU indicator During normal processor operation the CPU indicator should blink in 2 second intervals 1 second ON 1 second OFF 3 4 4 DEFAULT indicator DEFAULT indicator is ON when the device has the factory settings IP 192 168 0 1 ...

Страница 12: ... presence of power supply on the switch boards 3 5 Tamper sensor The optical tamper sensor is located inside the switch Figure 3 5 1 The optical tamper sensor is more reliable than sealed and limit switches because it does not get stuck and does not chatter Its operating principle is simple When the power supply unit is closed a curtain Figure 3 5 2 installed on its cover discontinues the optical ...

Страница 13: ...t switch has built in lightning protection modules that protect Ethernet ports and 230 VAC power circuits from common mode and differential electromagnetic interferences The switches are resistant to powerful microsecond pulse interferences according to GOST R 51317 4 5 as per Table 3 7 1 with performance criteria B temporary disruption of performance or functioning with further recovery without o...

Страница 14: ...PORTANT Grounding of the switch is mandatory for lightning protection 3 7 Automatic circuit breaker The switch is provided with an automatic circuit breaker for ease of maintenance Figure 3 7 Automatic circuit breaker ...

Страница 15: ...al Function section see the Configuration Manual The switch constantly 1 time per minute polls the IP camera If the switch does not receive a response then a one minute timer is started during this time the poll is repeated every 10 seconds If the camera has not responded within a minute the switch removes power from the camera for 10 seconds and supplies it again restarting the camera If the came...

Страница 16: ... particular cable which can affect the accuracy of the measurement To improve the accuracy of the cable tester it is recommended to calibrate it Note that calibration is not recommended for cables shorter than 10 meters 3 8 3 Remote camera polling Using the switch it is possible to ping any device on the network through the web interface which is convenient when solving network problems 4 Technica...

Страница 17: ... 1 Resetting the switch to factory settings Before start set the switch to default settings To do this press and hold the DEFAULT button until the DEFAULT indicator is ON The default IP address of the switch is 192 168 0 1 6 2 IP address setting All software functions of the switch can be managed configured and monitored using the built in WEB interface and Telnet Below is the description of WEB b...

Страница 18: ...enter the IP address http 192 168 0 1 Figure 6 2 Entering the IP address of the switch 6 3 User name and password setting Until the user name and password are set you will log in without entering this data After the password is set you will need to authenticate when you log in Figure 6 3 Entering user name and password IMPORTANT Note that the user name and password are case sensitive 6 4 Activatio...

Страница 19: ...n the wall The cabinet has four attachment points Marking of the attachment points is shown in Figure 7 1 Figure 7 1 Marking of attachment points IMPORTANT Drilling of the enclosure will lead to loss of the switch integrity and result in the loss of product warranty ...

Страница 20: ...ame For ease of operation the optical distribution frame can be removed from the cabinet The optical cable is pulled into PG13 5 cable glands The optical cable is attached to the metal base of the distribution frame with nylon ties Optical fibers are laid in a splice cassette for 12 shrinkable plastic sleeves Welded pigtails are connected to SC adapters located on the adapter panel Then the adapte...

Страница 21: ...nected to the automatic circuit breaker The grounding wire is connected to a special grounding screw Figure 7 4 Connection scheme IMPORTANT Grounding of the switch is mandatory Grounding resistance should not exceed 4 Ohm 7 5 Camera connection Camera connection recommendations 1 use a 4 pair shielded twisted pair at least category 5 2 use shielded RJ45 connections ...

Страница 22: ...he enclosure is missing or if the serial number has been changed removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals signs of treatment with aggressive chemicals or fluids severe contamination insects presence or signs of insects presence in case of improper connection and opera...

Страница 23: ...video surveillance systems operation and adjustment of equipment call 8 a m to 4 p m Moscow time 7 342 270 112 8 7 342 260 20 30 send an e mail to tfortis fort telecom ru All technical documentation is available at https tfortis com support dokumentaciya na produkciyu ...

Отзывы: