background image

4

 

 

1. Designation 

Device PSW-11- is a Multifunctional Gigabit Switch in street version designed 
for connection of one IP-camera by optics. This switch has two ports. First 
port is optical, the second - copper. The optical port is designed to connect it 
to  other  switches  (media  converters),  the  second  -  to  connect  the  video 
camera. 
 
Figure 1. Connection Scheme of the PSW-11  

Weatherproof version 

The  body  of  the  device  is  made  of  a  techno-polymer  that  is  resistant  to 
Stringent Operating Conditions. There is a protection from moisture and dust 
IP66. 
 

Operation in extreme temperatures 

The device has industrial hardware components that are characterized by an 
extended  temperature  range.  Using  industrial  SFP  modules  in  industrial 
version guarantees operation from -55°C to 50°C. 

Содержание PSW-11

Страница 1: ...1 Operation Manual PSW 11 Multifunctional Gigabit Switch for IP video surveillance systems Version 5...

Страница 2: ...y units is forbidden When connecting the computer to the switch remove PoE jumpers at this port For effective operation of lightning protection is required high quality grounding according to the ELC...

Страница 3: ...Restart of video cameras at their hanging 12 3 Technical parameters 12 4 Operation conditions 12 5 Presetting 13 5 1 Configuring PoE on port 13 5 2 Speed mode configuration for SFP port 13 5 3 Enablin...

Страница 4: ...the second to connect the video camera Figure 1 Connection Scheme of the PSW 11 Weatherproof version The body of the device is made of a techno polymer that is resistant to Stringent Operating Conditi...

Страница 5: ...e switch to the Power Supply 220V and excludes need in additional PSU Lightning protection Built in Lightning protection of Ethernet ports and 220V PSU reliably protects both the switch and connected...

Страница 6: ...6 2 Description 2 1 Appearance Figure 2 1 1 PSW 11 outside view Figure 2 1 2 PSW 11 inside view...

Страница 7: ...Element arrangement of PSW 11 During normal operation CPU indicator must light intermittently with a frequency of 2s 1 sec on 1 sec off PoE Jumpers LINK and PoE indicators RESTART jumper TIMER jumper...

Страница 8: ...he PoE standard terminology first one is named as mode A and the second mode B Power is supplied to video cameras installed into TFortis TH camera housing using mode A and mode B simultaneously I When...

Страница 9: ...igure 2 3 Power supply scheme over PoE in different cases TFortis TH camera housing Pairs 1 2 and 3 6 IEEE802 3af Pairs 4 5 and 7 8 Passive PoE Pairs 1 2 and 3 6 IEEE802 3af Pairs 4 5 and 7 8 Passive...

Страница 10: ...5 standard with a degree of rigidity according to Table 2 5 1 with performance criteria B Switches are resistant to dynamic changes in the voltage of the AC electrical network in accordance with stan...

Страница 11: ...tainability is preserved during fluctuations in supply voltage from 187 to 246 V 2 6 Cold start The most critical moment in the operation of the video camera is the process of its activation at low am...

Страница 12: ...ontrol of IEEE 802 3x supports IEEE802 3af 15 4 W at a port supports Passive PoE 15 4 W at a port data and PoE transmission distance up to 100m Power supply unit supply voltage 220V from 187V to 246V...

Страница 13: ...optical SFP module with the declared speed up to 155MGb operates only in 100M mode 5 3 Enabling Preheating of camera housings When the camera is turned on in the cold it may not start or even worse fa...

Страница 14: ...he product is shown on the Fig 6 1 1 Figure 6 1 Marking of the fastening IMPORTANT Drilling of the housing leads to a violation of the sealing of the entire commutator and as a consequence the loss of...

Страница 15: ...starting current appears and it exceeds the nominal value In order to avoid false alarms of the protection devices it is recommended to choose models with the characteristic C for a current of at lea...

Страница 16: ...number was changed removed or illegible if there are external and internal mechanical damages chips cracks deformation damage to the power cord breaks and cracks of connectors traces of chemicals cor...

Отзывы: