ELECTRICAL
4
Instrumentation Circuit
Symptom: Fan does not turn on.
Symptom: Engine oil pressure not detected.
Symptom: Engine oil pressure low with engine running.
Probable Cause
Remedy
Engine temperature is below 150° F (66°
C).
The fan motor (M4) does not turn on until the engine temperature reaches 150° F (66° C)
Faulty 30-amp fuse (F5)
Test 30-amp fuse (F5). (See “Fuse Test” on page 4-53.)
Faulty 10-amp fuse (F
8
)
Test 10-amp fuse (F
8
). (See “Fuse Test” on page 4-53.)
Faulty temperature sender.
Test the temperature sender (R5). (See “Engine Temperature Sender Test” on
Faulty fan relay.
Test the fan relay (K4). (See “Relays Test” on page 4-53.)
Faulty fan motor
Test the fan motor (M4). (See “Fan Motor Test” on page 4-61.)
Faulty wire harness
Check continuity between MCU (U1) terminal 3-02 and the temperature sender (R5).
Continuity must be indicated.
Check continuity between temperature sender (R5) and coolant temperature resistor(R2).
Continuity must be indicated.
Check continuity between ignition relay (K1) terminal
8
7 and coolant temperature resistor
(R2). Continuity must be indicated.
Check continuity between ignition relay (K1) terminal
8
7 and 10-amp fuse (F
8
). Continuity
must be indicated.
Check continuity between 10-amp fuse (F
8
) and fan relay (K4) terminal 30. Continuity
must be indicated.
Check continuity between 30-amp fuse (F5) and fan motor (M4) terminal 1. Continuity
must be indicated.
Check continuity between MCU (U1) terminal 2-04 and fan relay(K4) terminal
8
6.
Continuity must be indicated.
Check continuity between fan relay (K4) terminal
8
7 and the fan motor (M4) terminal 3.
Continuity must be indicated.
Check continuity between ground and fan relay(K4) terminal
8
5. Continuity must be
indicated.
Check continuity between ground and fan motor (M4) terminals 2 and 4. Continuity must
be indicated.
Faulty MCU.
Replace MCU
Probable Cause
Remedy
Faulty engine oil pressure switch.
With the key switch in the OFF position, check continuity between engine oil pressure
switch (SW11) and ground. Continuity must be indicated. If continuity is not indicated,
replace engine oil pressure switch.
Faulty engine oil pressure switch circuit.
Check continuity between engine oil pressure switch (SW11) terminal and MCU (U1)
terminal 6-11. Continuity must be indicated.
Probable Cause
Remedy
Low engine oil pressure.
Check engine oil pressure.
Faulty engine oil pressure switch.
If engine oil pressure tests good, replace engine oil pressure switch.
Содержание Jacobsen SLF530
Страница 2: ......
Страница 6: ......
Страница 9: ...SAFETY 673831 Rev A 1 3 1 Figure 1 1 MAR0230 1 2 2 3 4 5 6 7 8 9 10 10 10 11 12 13 14 15 ...
Страница 11: ...SAFETY 673831 Rev A 1 5 1 3008682 838363 105dB LWA 12 1 37 1 72 bar 20 25 psi 4323911 13 14 15 ...
Страница 44: ...3 18 673831 Rev A ENGINE 3 Page Intentionally Blank ...
Страница 60: ...4 16 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 64: ...4 20 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 72: ...4 28 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 76: ...4 32 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 80: ...4 36 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 84: ...4 40 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 126: ...4 82 673831 Rev A ELECTRICAL 4 Page Intentionally Blank ...
Страница 239: ...HYDRAULICS 673831 Rev A 6 45 6 Page Intentionally Blank ...
Страница 258: ...6 64 673831 Rev A HYDRAULICS 6 Page Intentionally Blank ...
Страница 286: ...7 28 673831 Rev A STEERING 7 Page Intentionally Blank ...
Страница 350: ...IX IX 12 673831 Rev A INDEX ...
Страница 351: ......